BayStack 450 10/100/1000 Series Switches302401-D Rev 00 1-81In this example, port 23 becomes the designated Monitor Port for switch S1 whenyou press Enter in response to the [Yes] screen prompt.The Monitoring Mode field [ Address A - > Address B ] indicates that alltraffic transmitted by address A to address B will be monitored by the StackProbeattached to Monitor Port 23.Figure 1-53. Port Mirroring Address-Based Screen ExampleNote: The screen data displayed at the bottom of the screen changes to showthe new currently active port mirroring configuration after you press Enter.Note: When you enter MAC addresses in this screen, they are also displayedin the MAC Address Table screen (see “MAC Address Table” on page 3-20).Port Mirroring ConfigurationMonitoring Mode: [ Address A -> Address B ]Monitor Unit/Port: [ /23 ]Unit/Port X: [ / ]Unit/Port Y: [ / ]Address A: [ 00-44-55-44-55-22 ]Address B: [ 00-33-44-33-22-44 ]Is your port mirroring configuration complete? [ Yes ]Currently Active Port Mirroring Configuration---------------------------------------------Monitoring Mode: -> Port X or Port Y -> Monitor Port: 23Port X: 25 Port Y: 24Use space bar to display choices, press or to select choice.Press Ctrl-R to return to previous menu. Press Ctrl-C to return to Main Menu.kombk.book Page 81 Tuesday, June 29, 1999 3:25 PM