Using the BayStack 450 10/100/1000 Series Switch3-26 302401-D Rev 00VLAN Port ConfigurationThe VLAN Port Configuration screen (Figure 3-10) allows you to configurespecified switch ports with the appropriate PVID/VLAN association that enablesthe creation of broadcast domains (see “Shared Servers” on page 1-40 for moreinformation about setting up broadcast domains).You can configure specified switch ports to filter (discard) all received taggedframes, untagged frames, or unregistered frames (see “IEEE 802.1Q Tagging” onpage 1-33).You can also prioritize the order in which the switch forwards packets, on aper-port basis (see “IEEE 802.1p Prioritizing” on page 1-53).Choose VLAN Port Configuration (or press c) from the VLAN ConfigurationMenu screen to open the VLAN Port Configuration screen.The Port Membership fields are displayed in six-port groups (for example, 1-6, 7-12,13-18). The number of ports displayed depends on the switch model or type ofoptional MDA installed in the Uplink Module slot.Default U (All ports are assigned as untagged members of VLAN 1.)Range U, T, and -Table 3-8. VLAN Configuration Screen Fields(continued)Field Descriptionkombk.book Page 26 Tuesday, June 29, 1999 3:25 PM