Using the BayStack 450 10/100/1000 Series Switch2-4 302401-D Rev 00The BayStack 450 switch can be mounted onto any appropriate flat, level surfacethat can safely support the weight of the switch and its attached cables, as long asthere is adequate space around the unit for ventilation and access to cableconnectors.To install the switch on a tabletop, shelf, or any other flat surface, follow thesesteps:1. Set the switch on the flat surface and check for proper ventilation.Allow at least 2 inches (5.1 cm) on each side for proper ventilation and5 inches (12.7 cm) at the back for power cord clearance.2. Attach rubber feet to each marked location on the bottom of the chassis.The rubber feet are optional but recommended to keep the unit from slipping.3. Attach all devices to the ports.See “Attaching Devices to the BayStack 450 Switch” on page 2-7.Installing the BayStack 450 Switch in a RackCaution: When mounting this device in a rack, do not stack units directly ontop of one another in the rack. Each unit must be secured to the rack withappropriate mounting brackets. Mounting brackets are not designed to supportmultiple units.Achtung: Wenn Sie dieses Gerät in einem Gerätegestell installieren, stellenSie die Geräte nicht direkt aufeinander. Jedes Gerät muß mit entsprechendenHalterungen im Gestell befestigt werden. Die Halterungen sind nicht dafürkonzipiert, mehrere Geräte zu tragen.Attention: Si cet appareil doit être encastré dans un rack, ne jamais empilerdirectement plusieurs unités les unes sur les autres. Chaque unité doit êtrecorrectement fixée avec les membrures appropriées. Les membrures ne sontpas conçues pour supporter le poids d'unités multiples.kombk.book Page 4 Tuesday, June 29, 1999 3:25 PM