IV - 49Section 4 - Appendix A - TroubleshootingOKI OkiLAN 6120e User’s GuideTCP/IPAppendix ATroubleshootingMain Status IndicatorUpon power-up, the main status indicator flashesorange. It changes to green when the OkiLAN 6120epasses self-test. The indicator stays orange if theOkiLAN 6120e fails self-test. If the indicator turnssolid orange due to an error, a configuration sheet willbe printed automatically. Check the error messagereported on the configuration sheet.Restoring the OkiLAN 6120e toFactory DefaultsIn most cases, the best way to restore the OkiLAN6120e to factory defaults is via telnet. However, if youare unable to connect to the device because of aconfiguration error, use the following method whichdoes not require a network connection.To restore the OkiLAN 6120e to factory defaults,complete the following steps:1. Power down the OkiLAN 6120e.2. While holding in the Print Configuration SheetTest button, power up the OkiLAN 6120e. Hold thebutton until the status indicator turns solid green.3. Power cycle the OkiLAN 6120e. It will haverestored itself to defaults.