- 32 -Calibrating the SensorIf the position of the label and thegap sensor position do not alignin relation to the regular usageposition, rotate the Sensor PositionAdjustment Dial to adjust theposition (go to step 3).Label5mm Width of theright edgeof the linerThe gap sensor position is set 16.5mm from the edge of the paper.If the width of the right edge ofthe liner is 10 mm or less, thenadjustments are not necessary.If the width of the right edge of theliner is 10 mm or more, then adjustthe gap sensor using the abovepositions as a rough estimate.If the corners of the label arerounded, then consider the positionof the radius of the corner.Refer to the following example ofadjusting the position.LabelRadius ofcorner5mm3 Rotate the Sensor Position AdjustmentDial to adjust the sensor position.ABDCMemoz If you rotate the Sensor Position Adjustment Dial indirection A→the sensor position moves in thedirection Cdirection B→the sensor position moves in thedirection D