18 (E)ENGLISHConnections~ AC IN75™ON ON ON ON ON ON ON ON75™CAMERA IN75™ 75™OFF OFF OFF OFF75™OFF 75™OFF 75™OFF 75™OFFAUDIOS-VIDEOOUTINOUT1 2 GNDINREC IN GNDGNDTIME ADJ INTAPE END OUTRESETALARMEXTTIMEROUTIN OUT WARNING/REC OUT EXT SW IN/VIDEO OUT VID EO OU TRS-232CMIC INREMOTE3 41 2 3 4 5 67 87 89 10 11 12 13 14 15 161 2 5 6No. 1 No. 163211 Set all 8 of the 75 Ω termination switches to theON position.2 Connect the 16 cameras to CAMERA INconnectors 1 to qV.3 Connect the TV monitor to the VIDEO OUTconnector.Example of connections to switch between 16 cameras for recordingO When connecting line-locked cameras, select ONfor the LL CAMERA item setting on the settingmenu shown on the P7 VIDEO OUT SEQUENCEscreen.The images on the monitor will shake fractionally:this is normal and not indicative of malfunctioning.O This unit does not contain a compensation circuit.Install a compensator when the total length of thecables (coaxial 3C-2V) used to connect thecameras exceeds 200 meters.There is no need to install a compensator if the totallength is under 400 meters if coaxial cables (5C-2V)with minimal transmission loss are used.This unit does not have an AGC (auto gain control) function forvideo signal level adjustment.Therefore, take due care with the 75 Ω termination for theperipheral equipment.