The underlining indicates the factory setting.500 VITC BLANK00000001BLANKTHRUThis selects whether to output the VITC signal at the positionswhich have been set by setup menu item No.501 (VITC POS-1)and No.502 (VITC POS-2).0: The VITC signal is not output.1: The VITC signal is output.[ [503 TCG REGEN000000010002TC&UBTCUBThis selects the signal to be regenerated when the TCG (timecode generator) is in the regeneration mode.0: Both the time code and user’s bit are regenerated.1: Only the time code is regenerated.2: Only the user’s bit is regenerated.[ [504 REGEN MODE0000000100020003AS&INASSEMINSRTSWThis selects when the time code is to be regenerated duringautomatic editing (assemble editing or insert editing).0: The time code is regenerated in assemble editing or insertediting.1: The time code is regenerated in assemble editing.2: The time code is regenerated in insert editing.3: The time code regeneration accords with the REGEN/PRESETswitch position.[501 VITC POS-1(525i mode)00000006001010L16L20LThis selects the position where the VITC signal is inserted.The same line as the one selected by setup menu item No.502(VITC POS-2) cannot be set.[ [(625i mode) 0000000400157L11L22L502 VITC POS-2(525i mode)00000008001010L18L20LThis selects the position where the VITC signal is inserted.The same line as the one selected by setup menu item No.501(VITC POS-1) cannot be set.[ [(625i mode) 0000000600157L13L22LItem SettingNo. Superimposeddisplay No. SuperimposeddisplayDescription of settingVTR1VTR241Setup menusTIME CODE menu