10.5 Positioning Table Settings (Configurator PMX)10-2510.5.3 Creating Positioning Data TableThe positioning data tables are divided into sheets for each axis, and 20 tables ranging no. 1to no. 20 can be set. For independent axis controlParameter name Default(Unit) SettingsOperation pattern E: EndpointSelect one from the following operation patterns.E: End point, C: Continuance point, P: Pass point, J: Speed pointControl method I:IncrementSelect either I: Increment or A: Absolute.I: Increment The position moves relatively from the currentposition by a specified amount.A: Absolute The position moves to an absolute coordinatedetermined by home return operation.X-axis movementamount 0 (pulse) Input a movement amount.Setting range: -1,073,741,824 to +1,073,741,823Acceleration/decelerationmethod L: Linear L: Linear (Fixed)Acceleration time 100 (ms) Set an acceleration time. Setting range: 1 to 10,000Deceleration time 100 (ms) Set a deceleration time. Setting range: 1 to 10,000Target speed 1000 (pps) Set a target speed. Setting range: 1 to 500,000Dwell time 0 (ms)Set a dwell time from the end of each positioning control of positioningoperation table to the next operation.Note that operations vary depending on operation patterns.When operation pattern is E(end point)Turns on the positioning endcontact after the elapse of thedwell time.When operation pattern is C(continuance point)Stops the motor operation forthe dwell time and start thenext operation.When operation pattern is P(pass point) This setting is ignored.When operation pattern is J(speed point)Setting range: 0 to 32,767