Positioning Function (H type)10-6610.11.3 Stop Operation During Repeat OperationWhen setting the repeat function, the operation at the time of deceleration stop varies asfollows. Operation at the time of deceleration stop (Repeating E-point control)When the unit detects a deceleration stop, the unit will come to a stop after repeatingpositioning control N+2 times. However, the unit will stop the control when reaching the setrepeat count. Operation at the time of deceleration stop (Repeating P-point control, C-pointcontrol)When the unit detects a deceleration stop, it stops the operation after repeating thepositioning control N+1 times. However, the unit will stop the control when reaching the setrepeat count.KEY POINTS• When a system stop is executed, the unit will stop the pulse outputimmediately without repetitive operations.• When an emergency stop is executed, the unit will stop the pulse outputafter a specified emergency stop setting time without repetitive operations.