9.3 Read/Write of PLS/PWM Counter Elapsed Value9-119.3 Read/Write of PLS/PWM Counter Elapsed Value9.3.1 Elapsed Value When Power Turns On• The default for the elapsed value when the power turns on is "0".• The count value when the power turns on can be set to any value as necessary. It can beset to an arbitrary value in the configuration menu of the tool software or user programs.9.3.2 Reading PLS/PWM Counter Elapsed ValueThe elapsed value can be read from the unit memory area.Example) Program to read the elapsed value of the counter CH0 for pulse output/PWM outputR0MV.SL S1:UM00170 DT1009.3.3 Changing PLS/PWM Counter Elapsed ValueThe elapsed value can be set to an arbitrary value using a user program as necessary.Example) Program to change the elapsed value of the counter CH0 for pulse output/PWMoutput to 100000R0MV.SL K100000 S1:UM00170( )DF Unit memory (UM) allocationSignal name CH0 CH1 CH2 CH3PLS/PWMcounter elapsedvalue areaUM00170-UM00171 UM00172-UM00173 UM00174-UM00175 UM00176-UM00177(Note): Values cannot be written into the "PLS/PWM counter elapsed value" area of the channel to which thepositioning function has been set with the H type.