Messages and Troubleshooting8-2 7612-A2-GB20-00June 1997Device MessagesThe Device Messages in Table 8-1, listed in alphabetical order, may appear in themessages area at the bottom of the ATI screens.Table 8-1. Device Messages (1 of 2)Device Message What Message Indicates What To DoBlank EntriesRemovedNew had been selectedfrom the Administer Loginsscreen, no entry was made,and Save was selected. No action needed. Reenter the Login ID,Password, and Access Level.Cannot Save – NoLogin IDs with AccessLevel 1An attempt was made tosave logins with AccessLevels 2 and 3 only.Create a Login with AccessLevel 1.Command Complete Action requested hassuccessfully completed.No action needed.Invalid Character (x ) 1 An invalid ASCII characterhas been entered.Reenter information using validcharacters.Invalid – NetworkInitiated CSU (or DSU)Loopback ActiveNetwork-initiated loopbackwas in progress whenanother selection wasmade.No action needed.Invalid Password Login is required and anincorrect password wasentered; access is denied. Try again. Contact your systemadministrator to verify yourpassword.Invalid – [ Test ]Already Active[Test] can be a CSU, DSU,or DTE Local Loopback, ora Send 511 or Monitor 511.The [test] was already inprogress when anotherselection was made. Allow test to continue. Select another test. Stop the test.Invalid TestCombinationA loopback or 511 patterntest was in progress whenStart was selected to startanother test, or was activeon the same or anotherinterface when Start wasselected. Wait until other test ends andmessage clears. Abort all tests from the Testmenu screen. Stop the test from the samescreen the test was startedfrom.Limit of six Login IDsreachedAn attempt to enter a newlogin ID was made, and thelimit of six login/passwordcombinations has beenreached.1. Delete another login/passwordcombination.2. Reenter the new login ID.1x is the character not being accepted.