Configuration Option TablesA-2 7612-A2-GB20-00June 1997Select . . . To Access the . . . To Configure the . . .System System Options, Table A-1 General systemoptionsNetwork Network Interface Options, Table A-2 DDS network interfaceData Port Data Port Options, Table A-3 DTE portEthernet Port Ethernet Port Options, Table A-4 10BaseT portTerminal Port Terminal Port Options, Table A-5 Terminal portTelnet Session Telnet Session Options, Table A-6 Telnet user interfaceSNMP General SNMP Management Options,Table A-7 SNMP NMS Security Options, Table A-8 SNMP Traps Options, Table A-9Management supportthrough SNMPAll changes to configuration options must be saved. Refer toSavingConfiguration Options in Chapter 3.System Options MenuFor System Options, refer to Table A-1. To access the System Options screen,follow this menu selection sequence:Main Menu →Configuration →Load Configuration From →Edit →SystemTable A-1. System Options (1 of 3)Operating ModePossible Settings: DDS, LADSDefault Setting: DDSThe unit’s operating mode depends upon the DSU’s application.DDS – Standard DDS network operation. The operating rate is either 56 kbps or64 kbps CC.LADS – The Local Area Data Set operating mode requires that the local and remoteunits are connected directly to each other. This is a point-to-point application; alsoknown as LDM.