Switch-on status COMPAX-M / -S105. Switch-on status5.1 Configuration when suppliedWhen supplied, COMPAX is not configured. Parameter P149 is set to "0":P149="0": COMPAX is not configured and switches to OFF mode when switchedon (24V DC and operating voltage) (motor switched off). In addition tothis, when switched on, all parameters (apart from bus settings P194,P195, P196 and P250) are set to their default values.P149="1": COMPAX is configured and once switched on (24V DC and operatingvoltage) tries to engage the motor.5.2 CommissioningMeaning of LEDs on the front panelCOMPAX-M / -SLED Color Meaning, when switched onReady green 24V DC present and initialization completeError red COMPAX - Error (E1...E56) present or COMPAX isinitialized.Mains moduleLEDredErrorLEDgreenReadyPossible errorsoff on no errorson off Heat sink temperature too high orerror in logic voltage (24V DC too low or unit is defective)Emergency stop is activated and ready contact isreleased.on on Ballast switching unit overload orundervoltage (<100V DC or <80V AC).COMPAX 1000SLStatus Red LED (H2) Green LED (H1)24V not available off off24V are switched on, boot up on offUnit OFF off blinkingUnit error; drive switched off on blinkingUnit error; drive powered on onUnit RUNNING off onCaution!If there is no control voltage, no displays will appear to indicatethat operating voltage is present.With Error E40, external enabling is missing with COMPAX 45XXS, COMPAX85XXS and COMPAX 1000SL (Hardware input).Note: