InterfacesDigital inputs and outputs147UnithardwareConnectorassignment / cableTechnical dataConfigurationPositioning andcontrol functionsOptimizationfunctionsInterfacesAccessories /optionsStatusParameterError list8.6.1.4 I/O assignment of variantsI12: final stage enableI13: measuring error compensation by external position measurementI14: release brakeO14: no measuring errorO16: no power to final stageI6: STOP ineffective during synchronization process.I1 & I6: BREAK interrupts the synchronization process.I12: Material simulationI13: Manual stepI14: Switches on mark referenceI15: Ends synchronous travel(The "Fast start" function is not possible)I16: Mark inputO5: Position reached at synchronization command (WAIT POSA, WAIT POSR)="0"; when the axis starts="1": after return run.O14: Synchronous comparatorO15: Chaff lengthO16: Reject lengthI14: Switches over the dimension referenceI15: Transmission factor selectionI16: Enable master nominal valueI12: Enable final stageI13: ="0": Decoupling ="1": CouplingI14: Mark inputI15: ="0": Disables auxiliary functions ; ="1": Enables auxiliary functionsI16: Enables master positionO7...O14: Digital auxiliary functions.O13/O14: Cannot be used via OUTPUT.O14: Mark not in mark window.O15: Lag warningO16: Synchronous runPlease refer to the instructions for the variant you areusing for up-to-date information!COMPAX XX30:Round tablecontrolCOMPAX XX50:Synchronouscycle controlCOMPAX XX60:ElectronictransmissionCOMPAX XX70:Cam control