Start-up manual COMPAX-M / -SDigital inputs and outputs (excluding COMPAX 1000SL)527.9 Interfaces7.9.1 Digital inputs and outputs (excluding COMPAX 1000SL)The inputs and outputs have PLC voltage levels (High signal = 24V DC)X8PinAssignment Meaning1. Input I1 SHIFT ="0" ="1"2. Input I2 Manual+ Find machine zero3. Input I3 Manualñ Approach real zero4. Input I4 Quit Teach real zero5. Input I5 Start -6. Input I6 Stop (interruptdata record)Break (breaks offdata record)7. Input I78. Input I8Freely assignable in the standard unit.9. Output O1 ="1":No fault="0":errors E1 ... E58; the drive does notaccept any positioning commands.After "Power on" O1 remains at "0" until afterthe self test.10. Output O2 ="1":No warning="0":error ≥ E5811. Output O3 Machine zero has been approached12. Output O4 Ready for start13. Output O5 Programmed set point reached14. Output O6 Idle after stop15. Output O7Connectors:PhoenixMC1.5/16-ST-3.814 5 6 7 8 9 10 11 1213 14 15 161 2 316. Output O8Freely assignable in the standard unit.The "SHIFT signal" (I1) must be assigned before or at the same time as therelevant input.X10PinAssignment Meaning1. Input I92. Input I103. Input I114. Input I125. Input I136. Input I147. Input I158. Input I169. Output O910. Output O1011. Output O1112. Output O1213. Output O1314. Output O1415. Output O15Connector:PhoenixMC1.5/16-ST-3.814 5 6 7 8 9 10 11 1213 14 15 161 2 316. Output O16Freely assignable in the standard unit.Note the assignment for unit variants and for special functions.Assignment of X8(Input/Output)Assignment ofX10 (Input/Output)