Start-up manual COMPAX-M / -S64Technical data7.10 Technical dataPower characteristicsFunctional capability• Position, speed and current controller.• IGBT final stage protected from short circuits andground/earth faults.• Digital positioning controller.• Motion controller.Supported motors/resolvers• Sine-commuted synchronous motors up to a max.speed of 9000 rpm.• Asynchronous motors.• Supported resolvers:• Litton: JSSBH-15-E-5JSSBH-21-P4RE-21-1-A05RE-15-1-B04• Tamagawa: 2018N321 E64• Siemens: 23401-T2509-C202• SinCos support (Stegmann).• 3-phase synchronous linear motors 12• Sine-cosine linear encoder (1V ss ) or TTL(RS422)• Digital Hall sensor commutation (5V).Output data for individual unitsUnitCOMPAX .Nom.cur-rent [Aeff]Peak current[Aeff] <5sPower[kVA]with mains supply: 230V AC10XXSL 2.5 5.0 1.025XXS 6.3 12.6 2.5at mains supply: 400V AC45XXS 6.5 13.0 4.585XXS 12.5 25.0 8.6P1XXM 5.5 8.5 3.802XXM 6.5 8.5 4.505XXM 11.5 17.0 8.015XXM 25.0 50.0 17.035XXM 50.0 100.0 35.0with mains supply: 460V AC45XXS 5.4 13.0 4.585XXS 10.5 25.0 8.6P1XXM 4.5 8.5 3.802XXM 5.4 8.5 4.505XXM 9.6 17.0 8.015XXM 21.0 50.0 17.035XXM 42.0 100.0 35.012 Reduced nominal data apply for linear motors; see Page 177.CE conformity• EMC immunity/emissions as per EN61800-3.• Safety: VDE 0160/EN 50178.Supply voltage (limit values)COMPAX-M (NMD)• 3 * 80V AC - 3 * 500V AC; 45-65Hz.COMPAX 35XXM• 3 * 250V - 3 * 500V AC; 45 - 65 Hz.COMPAX 25XXS• 3 * 80V AC - 3 * 250V AC; 45 - 65 Hz1 * 100V AC-1 * 250V AC; 45-65HzCOMPAX 10XXSL• 1 * 100V AC-1 * 250V AC; 45-65HzCOMPAX 45XXS/85XXS• 3 * 80V AC - 3 * 500V AC; 45-65Hz.Mains supply fuse protectionK circuit breaker or similar Neozed fusible cut-out.• NMD (COMPAX-M)NMD10: 16A (K circuit breaker: 20A) NMD20:35A• COMPAX 35XXM: 62A• COMPAX 25XXS: 1x230V AC: 16A3 * 230V AC: 10A• COMPAX 10XXSL: 16A• COMPAX 45XXS/85XXS: 16ADC bus voltage• 300V DC with 3(1) * 230V AC.• 560V DC of 3 * 400V AC supply.• 650V DC with 3 * 460V AC.Output voltage to motorIgnoring power losses, motor output rating is themaximum motor output voltage of the AC supplyvoltage availableBraking operation• Storable energy• NMD10/20: 1100μF / 173Ws• CPMPAX 35XXM:3450μ / 542Ws• COMPAX 25XXS: 1000μF/27Ws• COMPAX 45XXS: 330μF/52Ws• COMPAX 85XXS: 500μF/80Ws• COMPAX 1000SL: 660μF/17Ws• Ballast resistances (see Page 193)Control voltage• 24V DC ±10%, Ripple <1V SSCurrent required:• 1.3A for COMPAX 35XXM.• 1A for COMPAX 45XXS/85XXS.