owner's information28 | City Series CV60E-1WARNING: Do not operate appliancewith the glass front removed,cracked, or broken. Replacement ofthe glass should be done by a licensedor qualified service person.3. Check for evidences of excessive condensation,such as water droplets forming in the innerliner, and subsequently dripping out the joints,Continuous condensation can cause corrosionof caps, pipe, and fittings. It may be causedby having excessive lateral runs, too manyelbows, and exterior portions of the systembeing exposed to cold weather.4. Inspect joints, to verify that no pipe sections orfittings have been disturbed, and consequentlyloosened. Also check mechanical supports suchas Wall Straps, or plumbers' tape for rigidity.Log ReplacementThe unit should never be used with broken logs.Turn off the gas valve and allow the unit to coolbefore opening door and carefully remove the logs.(The pilot light generates enough heat to burnsomeone.) If for any reason a log should needreplacement, you must use the proper replacementlog. The position of these logs must be as shownin the diagrams under Log Installation.Note: Improper positioning of logs maycreate carbon build-up and willseverely alter the unit's performancewhich is not covered under warranty.GlassYour Regency® fireplace is supplied with hightemperature 5mm-Tempered outer glass & 5mm-Ceramic inner glass. If your glass requires cleaning,we recommend using an approved glass cleaneravailable at all authorized dealers. Do not useabrasive materials or ammonia based cleaners.CAUTION & WARNINGS:* Do not clean when the glass is hot.* The use of substitute glass will void allproduct warranties.* Care must be taken to avoid breakage ofthe glass.* Do not strike or abuse the glass.* Do not operate this fireplace without theglass front or with a cracked or brokenglass front.* Wear gloves and safety glasses when removingdamaged or broken glass.* Replacement of the glass panels should bedone by a licensed or qualified service person.Glass ReplacementIn the event that you break your glass by impact,purchase your replacement from an authorizedRegency dealer only. Replacement glass is shippedalready installed into the door frame. Reinstall as perGlass Installation in the "Glass Installation" section.Replacement Glass PartNumbersOuter Safety Glass Front - Tempered(Part# 940-519/P)Inner Glass Front - Ceramic (Part# 940-518/P)Maintenance Instructions1. Always turn off the gas valve before cleaning.For relighting, refer to lighting instructions. Keepthe burner and control compartment clean bybrushing and vacuuming at least once a year.When cleaning the logs, use a soft clean paintbrush as the logs are fragile and easily damaged.2. Clean appliance and door with a damp cloth(never when unit is hot). Never use an abrasivecleaner. The glass should be cleaned with a gasfireplace glass cleaner. The glass should becleaned when it starts looking cloudy.3. The fireplace is finished in a heat resistant paintand should only be refinished with heat resistantpaint. Regency® uses StoveBright Paint - MetallicBlack #6309.4. Make a periodic check of burner for properposition and condition. Visually check the flameof the burner periodically, making sure the flamesare steady; not lifting or floating. If there is aproblem, call a qualified service person.5. The appliance and venting system must beinspected before use, and at least annually, bya qualified field service person, to ensure thatthe flow of combustion and ventilation air is notobstructed.Note: Never operate the appliance withoutthe glass properly secured in place.6. Do not use this appliance if any part has beenunder water. Immediately call a qualified servicetechnician to inspect the appliance and toreplace nay part of the control system and anygas control which has been under water.7. In the event this appliance has been servicedcheck that the vent-air system has been properlyresealed & reinstalled in accordance with themanufacturer's instructions.8. Verify operation after servicing.General Vent MaintenanceConduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:1. Check the Venting System for corrosion in areasthat are exposed to the elements. These willappear as rust spots or streaks, and in extremecases, holes. These components should bereplaced immediately.2. Remove the Cap, and shine a flashlight down theVent. Remove any bird nests, or other foreignmaterial.