installer's information30 | City Series CV60E-1Installation Checklist1. Locate appliance. Refer to the followingsections:a) Locating Your Fireplaceb) Clearancesc) Combustible Mantel Clearancesd) Framing & Finishinge) Venting. See the "Venting Introduction" to"Venting Arrangements" sections.2. Assemble Standoffs. Refer to the "Unit AssemblyPrior to Installation" section. (NOTE: must bedone before installing unit into fireplace.)3. Install vent. See the "Horizontal Installations"to "Installation Procedures" sections.4. Wire 120 volt AC power to the suppliedreceptacle box located on the lower left-handside of appliance. The Duplex receptacle andcover are included in the manual package.Note : This heater does not require a 120 voltAC supply for burner operation, but is highlyrecommended as a primary power source toeliminate the need for 4 AA batteries. Batteriesshould be used as a secondary power source.120 Volt AC power is also required for the lights.5. Install the junction box supplied with theappliance. Install the remote battery box insidethe junction box. Hook the battery box to thewire marked "receiver" - this will enable burneroperation. If 120 Volt AC power was broughtto appliance, batteries are not required.6. Make gas connections. Test the pilot. Must be asper diagram. Refer to the "Gas Line Installation"& "Pilot Adjustment" sections.7. Install standard and optional features. Referto the following sections where applicable:a. Barrier Safety Glassb. Firebox (inner) glassc. Log Setd. Fireglasse. Ceramic stones or other approved mediaf. Painted, enamel, or glass panels (panelsrequired)g. Optional Framing Kith. Heatwave Kiti. HeatWave Kit Adaptor8. Plug 3 prong plug for the lights into thereceptacle. The 3 prong plug will be locatednear the gas valve on the appliance.9. Final check.Before leaving this unit with the customer, theinstaller must ensure that the appliance is firingcorrectly and operation fully explained to customer.General Safety Information1. The appliance installation must conform withlocal codes or, in the absence of local codes, withthe current Canadian or National Gas Codes,CAN1-B149 or ANSI Z223.1 Installation Codes.2. See general construction and assemblyinstructions. The appliance and vent should beenclosed.3. This appliance must be connected to thespecified vent and termination cap to the outsideof the building envelope. Never vent to anotherroom or inside a building. Make sure that thevent is fitted as per Venting instructions.4. Inspect the venting system annually for blockageand any signs of deterioration.5. Venting terminals shall not be recessed into awall or siding.6. Any safety glass removed for servicing mustbe replaced prior to operating the appliance.7. To prevent injury, do not allow anyone who isunfamiliar with the operation to use the fireplace.8. Wear gloves and safety glasses for protectionwhile doing required maintenance.9. Be aware of electrical wiring locations in wallsand ceilings when cutting holes for termination.10. Under no circumstances should this appliancebe modified. Parts that have to be removed forservicing should be replaced prior to operatingthis appliance.11. Installation and any repairs to this applianceshould be done by a qualified service person.A professional service person should be calledto inspect this appliance annually. Make it apractice to have all of your gas applianceschecked annually.12. Do not slam shut or strike the glass door.13. Under no circumstances should any solid fuels(wood, paper, cardboard, coal, etc.) be used inthis appliance.14. The appliance area must be kept clear and freeof combustible materials, (gases and otherflammable vapours and liquids).This includes:1. Clocking the appliance to ensure the correctfiring rate (rate noted on label 39,000 Btu/hNG/ 36,000 Btu/h LP) after burning appliancefor 15 minutes.2. If required, adjusting the primary air to ensurethat the flame does not carbon. First allow theunit to burn for 15-20 min. to stabilize.CAUTION: Any alteration to the productthat causes sooting or carboning that resultsin damage is not the responsibility of themanufacturer.Heatwave Duct SystemOptional KitThe HeatWave Air Duct Kit increases theeffectiveness of your fireplace by dispersing warmair from the fireplace to remote locations in thesame room or other rooms in your home.Up to two kits may be installed on the fireplace.The HeatWave Duct Kit has different clearanceand framing requirements, check the HeatWavemanual for details.NOTES• One adaptor kit (part #946-766) must beused with each HeatWave system (part#946-753).• Using the optional HeatWave kit does notreduce the size of the ventilation opening,which must be a minimum of 180 sq. in.