Regency City CV60E-1 Owners & Installation Manual
Also see for City CV60E-1: Owners & installation manual
62 ............................................. |City Series CV60E-1installation62 | City Series CV60E-1Page 2920-385 04.29.21Vertical Termination5" (127 mm) x 8" (203 mm) Venting - Vertical Flex Vent Kit for North America(Part #946-772)Diagram 414. Put a bead of caulking on the exterior between the outer pipe andflashing to prevent water from penetrating the chimney system.15. Slide storm collar over pipe length until it reaches the flashing.16. Install termination cap by twist locking it.17. Secure the flashing to the roof using screwsNote: Any closets or storage spaces which the vent passesthrough must be enclosed.Diagram 3Diagram 3b13. Slide the finished length up towards the flashing ensuring thelength of pipe is a minimum of 2 feet (0.61 m) measured fromthe top of the roof. Level the chimney and secure using the roofsupport provided with kit to bottom side of the roof as shown usinga minimum of 2 screws per side- see Diagram 3b. See Diagram4 for roof pitch and height requirements. See Diagram 3a forsecuring method if 2 feet (0.61 m) is insufficient and additionallengths are required, this may be purchased separately. SeeSimpson Duravent components list in the instruction manual forpart numbers.City Series ACB60E | 61installation920-328 09.18.20Diagram 414. Put a bead of caulking on the exterior between the outer pipe and flashingto prevent water from penetrating the chimney system.15. Slide storm collar over pipe length until it reaches the flashing.16. Install termination cap by twist locking it.17. Secure the flashing to the roof using screwsNote: Any closets or storage spaces which the vent passes through mustbe enclosed.Roof Pitch Minimum Vent HeightMetersflat to 7/12 0.61over 7/12 to 8/12 0.61over 8/12 to 9/12 0.61over 9/12 to 10/12 0.76over 10/12 to 11/12 0.99over 11/12 to 12/12 1.22over 12/12 to 14/12 1.52over 14/12 to 16/12 1.83over 16/12 to 18/12 2.13over 18/12 to 20/12 2.29over 20/12 to 21/12 2.44Diagram 3Diagram 3aDiagram 3b13. Slide the finished length up towards the flashing ensuring the length ofpipe is a minimum of 0.6m measured from the top of the roof. Level thechimney and secure using the roof support provided with kit to bottomside of the roof as shown using a minimum of 2 screws per side- seeDiagram 3b. See Diagram 4 for roof pitch and height requirements. SeeDiagram 3a for securing method if 0.6m is insufficient and additionallengths are required, this may be purchased separately. See SimpsonDuravent components list in the instruction manual for part numbers.Flex PipeCeiling FirestopRoof Support / BraceFlashingStorm CollarTermination CapCeiling FirestopEnclosureFlex PipeCeiling FirestopRoof SupportFlashingElbow SupportTermination CapStorm CollarCeiling FirestopSupport to prevent saggingEnclosureCeiling firestopFlashingTermination CapStorm CollarRoof supportCeiling firestop2EnclosureCeiling firestopFlashingTermination CapStorm CollarRoof supportCeiling firestopRoof PitchMinimum VentHeight Minimum VentHeightFeet Metersflat to 7/12 2 0.61over 7/12 to 8/12 2 0.61over 8/12 to 9/12 2 0.61over 9/12 to 10/12 2.5 0.76over 10/12 to 11/12 3.25 0.99over 11/12 to 12/12 4 1.22over 12/12 to 14/12 5 1.52over 14/12 to 16/12 6 1.83over 16/12 to 18/12 7 2.13over 18/12 to 20/12 7.5 2.29over 20/12 to 21/12 8 2.44City Series ACB60E | 61installation920-328 09.18.20Diagram 414. Put a bead of caulking on the exterior between the outer pipe and flashingto prevent water from penetrating the chimney system.15. Slide storm collar over pipe length until it reaches the flashing.16. Install termination cap by twist locking it.17. Secure the flashing to the roof using screwsNote: Any closets or storage spaces which the vent passes through mustbe enclosed.Roof Pitch Minimum Vent HeightMetersflat to 7/12 0.61over 7/12 to 8/12 0.61over 8/12 to 9/12 0.61over 9/12 to 10/12 0.76over 10/12 to 11/12 0.99over 11/12 to 12/12 1.22over 12/12 to 14/12 1.52over 14/12 to 16/12 1.83over 16/12 to 18/12 2.13over 18/12 to 20/12 2.29over 20/12 to 21/12 2.44Diagram 3Diagram 3aDiagram 3b13. Slide the finished length up towards the flashing ensuring the length ofpipe is a minimum of 0.6m measured from the top of the roof. Level thechimney and secure using the roof support provided with kit to bottomside of the roof as shown using a minimum of 2 screws per side- seeDiagram 3b. See Diagram 4 for roof pitch and height requirements. SeeDiagram 3a for securing method if 0.6m is insufficient and additionallengths are required, this may be purchased separately. See SimpsonDuravent components list in the instruction manual for part numbers.Flex PipeCeiling FirestopRoof Support / BraceFlashingStorm CollarTermination CapCeiling FirestopEnclosureFlex PipeCeiling FirestopRoof SupportFlashingElbow SupportTermination CapStorm CollarCeiling FirestopSupport to prevent saggingEnclosureCeiling firestopFlashingTermination CapStorm CollarRoof supportCeiling firestop2Diagram 3a |
Related manuals for Regency City CV60E-1
Regency City CB60E-1 Owners & Installation Manual
Regency City CP60E Owners & Installation Manual
Regency City CV60E Series Owners & Installation Manual
Regency City CV60EPV-NG Owners & Installation Manual
Regency City CST60E Owners & Installation Manual
Regency City CB50E Owners & Installation Manual
Regency City CV72E-12 Owners & Installation Manual
Regency City CST50E Owners & Installation Manual
Regency CV40E-12 Owners & Installation Manual
Regency City ACB60ENG Owners & Installation Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine