Regency City CV60E-1 Owners & Installation Manual
Also see for City CV60E-1: Owners & installation manual
36 ............................................. |City Series CV60E-1installation36 | City Series CV60E-1ClearancesNote: The clearances listed below are minimum distances unless otherwise stated.A major cause of chimney-related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importancethat this fireplace and vent system be installed only in accordance with these instructions.Flue Clearances to CombustiblesHorizontal - Top 3"Horizontal - Side 2"Horizontal - Bottom 2"Vertical 2"Passing through wall/floor/ceiling - whenfirestop is used.1-1/2"Note: This appliance uses 5" x 8" venting.28 | City Series CV60EinstallationClearances CV60EThe clearances listed below are Minimum distances unless otherwise stated:A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that thisfireplace and vent system be installed only in accordance with these instructions.Clearance: single sided Dimension Measured From:A1: :Mantel Height (min.) ** Top of Fireplace OpeningA: From Floor 10 1/4” (260 mm)" Bottom of Fireplace OpeningB: Sidewall (on one side) 8" (203mm) Side of Fireplace OpeningC: Enclosure width 65 11/16" (1668mm) Side of Fireplace OpeningD: Mantel Depth (max.) **E: Alcove Width 109.5” (2781mm) Sidewall to Sidewall (Minimum)F: Alcove Depth 35" (889mm) Front to Unit (Maximum)H: Convection Air Outlet *180 square inchesG: Convection Air Outlet Opening Offset *0-2" (0-51mm)K: Minimum clearance to celing 1 3/4” (44 mm)M: Clearance to Sprinkler Head (Min.) 36" (914mm) PerpendicularFrom back wall to chase frontfrom chase grillHearth 0" hearth required** See mantel clearances chart in this manual.Flue Clearances to CombustiblesHorizontal - Top 3"Horizontal - Side 2"Horizontal - Bottom 2"Vertical 2"Passing through wall/floor/ceiling - when 1-1/2"Note: This appliance uses 5" x 8" venting.AlcoveEFDA1BAJGHL* A minimum of 180 squareinches of open area, notlower than 0-2" from top ofenclosure, required for allinstallationsSide viewMChase grillSprinklerJ: Opening Height 18" (457 mm) Bottom/Top of Fireplace OpeningTop of chase to ceiling20-5/16" (516mm)I: Framing depthFrom base of unit to ceiling81 1/4" (2038 mm)L: Ceiling heightAlcoveClearance Dimension Measured From:A1: Mantel Height (min.) ** Top of Fireplace OpeningA: From Floor (min.) 10-1/4" (260 mm) Bottom of fireplace openingB: Sidewall (on one side) min. 8" (203 mm) Side of fireplace openingB1: Sidewall (on one side) min. 24" (610 mm) Side air outlet to side wall (min.)C: Enclosure Width (min.) 65-11/16" (1668 mm) Side of fireplace openingD: Mantel Depth (max.) **E: Alcove Width 109-1/2" (2781 mm) Sidewall to sidewall (minimum)F: Alcove Depth 35" (889 mm) Front to unit (maximum)G: Convection Air Outlet Opening Offset(min.)H: Convection Air Outlet*0-2" (0-51 mm)*180 in2 (1161 cm2)Max. offset from top of chase enclosureI: Framing Depth (min.) 20-5/16" (516 mm) From back wall to chase frontJ: Opening Height 18" (457 mm) Bottom/top of fireplace openingK: minimum clearance to ceiling 1-3/4" (44 mm) Top of chase to ceilingL: Chase Enclosure (min.) 81-1/4" (2064 mm) From base of unit/floor to top of enclosureM:Clearance to Sprinkler Head (min.) 36" (914mm) Perpendicular from chase grillHearth 0" No hearth required** See mantel clearances chart in the manual.28 | City Series CV60EinstallationClearances CV60EThe clearances listed below are Minimum distances unless otherwise stated:A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that thisfireplace and vent system be installed only in accordance with these instructions.Clearance: single sided Dimension Measured From:A1: :Mantel Height (min.) ** Top of Fireplace OpeningA: From Floor 10 1/4” (260 mm)" Bottom of Fireplace OpeningB: Sidewall (on one side) 8" (203mm) Side of Fireplace OpeningC: Enclosure width 65 11/16" (1668mm) Side of Fireplace OpeningD: Mantel Depth (max.) **E: Alcove Width 109.5” (2781mm) Sidewall to Sidewall (Minimum)F: Alcove Depth 35" (889mm) Front to Unit (Maximum)H: Convection Air Outlet *180 square inchesG: Convection Air Outlet Opening Offset *0-2" (0-51mm)K: Minimum clearance to celing 1 3/4” (44 mm)M: Clearance to Sprinkler Head (Min.) 36" (914mm) PerpendicularFrom back wall to chase frontfrom chase grillHearth 0" hearth required** See mantel clearances chart in this manual.Flue Clearances to CombustiblesHorizontal - Top 3"Horizontal - Side 2"Horizontal - Bottom 2"Vertical 2"Passing through wall/floor/ceiling - when 1-1/2"Note: This appliance uses 5" x 8" venting.AlcoveEFDA1BAJGHL* A minimum of 180 squareinches of open area, notlower than 0-2" from top ofenclosure, required for allinstallationsSide viewMChase grillSprinklerJ: Opening Height 18" (457 mm) Bottom/Top of Fireplace OpeningTop of chase to ceiling20-5/16" (516mm)I: Framing depthFrom base of unit to ceiling81 1/4" (2038 mm)L: Ceiling height*A minimum of 180 squareinches of open area, notlower than 0-2" from topof enclosure, required forall installations.LChase grillSprinklerSide viewMCaution RequirementsThe top, back and sides of the fireplace aredefined by standoffs. The metal ends ofthe standoff may NOT be recessed intocombustible construction.WARNINGFire hazard is an extreme riskif these clearances (air space) tocombustible materials are not adheredto. It is of greatest importance that thisfireplace and vent system be installed onlyin accordance with these instructions.The HeatWave DuctKit has different clear-ance and framing re-quirements, check theHeatWave manualfor details. |
Related manuals for Regency City CV60E-1
Regency City CB60E-1 Owners & Installation Manual
Regency City CP60E Owners & Installation Manual
Regency City CV60E Series Owners & Installation Manual
Regency City CV60EPV-NG Owners & Installation Manual
Regency City CST60E Owners & Installation Manual
Regency City CB50E Owners & Installation Manual
Regency City CV72E-12 Owners & Installation Manual
Regency City CST50E Owners & Installation Manual
Regency CV40E-12 Owners & Installation Manual
Regency City ACB60ENG Owners & Installation Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine