PLC-WM4500/WM4500L Expand Serial Command Functional Specifications30/788.7.3 CF_VSCALE CommandCommand “CF_VSCALE_%1” [CR]%1“035” ---------------------- +35“031” ---------------------- +31:“002” ---------------------- +2“001” ---------------------- +1“000” ---------------------- ±0“ 01” --------------------- 1“ 02” --------------------- 2:“ 31” --------------------- 31“ 32” --------------------- 32“UP” --------------------- Increment setting value of Vscale by 1“DN” --------------------- Decrement setting value of Vscale by 1DetailsSet Vscale (Available only in the normal Power ON status)*When the screen mode is not in “Custom”, projector changes image mode intoCustom by receiving this command.*When there is no signal detected, projector returns 101 and the command doesnot execute.Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]8.7.4 CF_VPOS CommandCommand “CF_VPOS_%1” [CR]%1“015” --------------------- +15“014” --------------------- +14:“002” --------------------- +2“001” --------------------- +1“000” --------------------- ±0“ 01” --------------------- 1“ 02” --------------------- 2:“ 14” --------------------- 14“ 15” --------------------- 15“UP” --------------------- Increment setting value of Vposition by 1“DN” --------------------- Decrement setting value of Vposition by 1DetailsSet V Position (Available only in the normal Power ON status)*When the screen mode is not in “Custom”, projector changes image mode intoCustom by receiving this command.*When there is no signal detected, projector returns 101 and the command doesnot execute.Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]