PLC-WM4500/WM4500L Expand Serial Command Functional Specifications63/789.9 Lamp Status Read Command9.9.1 CR_LAMPREPL CommandCommand “CR_LAMPREPL” [CR]Details Get information of Lamp Replacement timeAcceptable “000_%1” [CR]%1 “1Y” ----------------- indicates over lamp replacement time“1N” ----------------- indicates under lamp replacement timeResponseUnacceptable “?” [CR]9.9.2 CR_LAMPH CommandCommand “CR_LAMPH” [CR]Details Get Lamp running time (in hours)* return actual lamp running timeAcceptable “000_%1” [CR]%1 “00000 - 99999”ResponseUnacceptable “Error Code” [CR]9.9.3 CR_LAMPCORRESPH CommandCommand “CR_LAMPCORRESPH” [CR]Details Get Lamp running time (in hours)*return lamp running time multiplied by a coefficient (not actual running time)Acceptable “000_%1” [CR]%1 “00000 – 99999”ResponseUnacceptable “Error Code” [CR]9.9.4 CR_LAMPMODE CommandCommand “CR_LAMPMODE” [CR]Details Get setting status of Lamp modeAcceptable “000_%1” [CR]%1“NORMAL” --------------- Lamp mode is Normal status“ECO1” -------------------- Lamp mode is Eco1 status“ECO2” -------------------- Lamp mode is Eco2 status“AUTO” -------------------- Lamp mode is Auto statusResponseUnacceptable “?” [CR]9.9.5 CR_LAMPSTS CommandCommand “CR_LAMPSTS” [CR]Details Get Lamp statusAcceptable “000_%1” [CR]%1“1I” ------------------------ Lamp is ON“1O” ---------------------- Lamp is OFF“1X” ----------------------- Lamp FailureResponseUnacceptable “Error Code” [CR]