PLC-WM4500/WM4500L Expand Serial Command Functional Specifications67/789.11.5 CR_LOGO CommandCommand “CR_LOGO” [CR]Details Get setting status of LogoAcceptable “000_%1” [CR]%1“DFLT” ----------------------------- Default Logo is enabled“USER” --------------------------- User is enabled“OFF” ------------------------------ Logo is disabledResponseUnacceptable “Error Code” [CR]9.11.6 CR_LOGOLOCK CommandCommand “CR_LOGOLOCK” [CR]Details Get setting status of Logo Lock functionAcceptable “000_%1” [CR]%1 “ON” --------------------------- Logo Lock is ON“OFF” ------------------------- Logo Lock is OFFResponseUnacceptable “Error Code” [CR]9.11.7 CR_PIP CommandCommand “CR_PIP” [CR]Details Get status of “Picture in Picture” settingAcceptable “000_%1” [CR]%1“OFF” -------------------- Off is selected“USER1” ---------------- User1 is selected“USER2” ---------------- User2 is selected“USER3” ---------------- User3 is selected“USER4” ---------------- User4 is selected“USER5” ---------------- User5 is selectedResponseUnacceptable “Error Code” [CR]9.11.8 CR_PIPMODE CommandCommand “CR_PIP” [CR]Details Get Mode in “Picture in Picture”Acceptable “000_%1” [CR]%1 “PINP” ----------------- P in P is selected“PBYP” ---------------- P by P is selectedResponseUnacceptable “Error Code” [CR]