PLC-WM4500/WM4500L Expand Serial Command Functional Specifications72/789.11.25 CR_P-MANETIME CommandCommand “CR_P-MAETIME” [CR]Details Get setting time for starting Power Management functionAcceptable “000_%1” [CR]%1 “001 – 030” ----------------------- 1 to 30 minutesResponseUnacceptable “Error Code” [CR]9.11.26 CR_STANDBYMODE CommandCommand “CR_STANDBYMODE” [CR]Details Get setting status of Standby modeAcceptable “000_%1” [CR]%1 “ECO” ----------------------- Less standby electricity“NORMAL” -------------- Normal standby electricityResponseUnacceptable “Error Code” [CR]9.11.27 CR_ON-STA CommandCommand “CR_ON-STA” [CR]Details Get Direct on setting statusAcceptable “000_%1” [CR]%1 “ON” -------------------------- Direct on is active“OFF” ------------------------ Direct on is inactiveResponseUnacceptable “Error Code” [CR]9.11.28 CR_POINTER CommandCommand “CR_POINTER” [CR]Details Get setting status of PointerAcceptable “000_%a” [CR]%1“ARROW” ---------------------Arrow Pointer mode“FINGER” ---------------------Finger Pointer mode“LASER” ---------------------- Dot Pointer modeResponseUnacceptable “Error Code” [CR]9.11.29 CR_PTIMEMODE CommandCommand “CR_PTIMEMODE” [CR]Details Get setting status of count up/down mode in P-timerAcceptable “000_%a” [CR]%1 “COUNTUP” -------------------- Set P-timer to Count up mode“COUNTDN” -------------------- Set P-timer to Count down modeResponseUnacceptable “Error Code” [CR]