PLC-WM4500/WM4500L Expand Serial Command Functional Specifications54/789.4.16 CR_IMAGE CommandCommand “CR_IMAGE” [CR]Details Get image setting statusAcceptable “000_%1” [CR]%1“DYNAMIC” -------------------------------- Dynamic“STAND” ------------------------------------ Standard“REAL” ------------------------------------ Real“NATURAL” -------------------------------- Natural“CINEMA” ---------------------------------- Cinema“CUSTOM1” ------------------------------- “Image1”“CUSTOM2” ------------------------------- “Image2”“CUSTOM3” ------------------------------- “Image3”“CUSTOM4” ------------------------------- “Image4”“CUSTOM5” ------------------------------- “Image5”“CUSTOM6” ------------------------------- “Image6”“CUSTOM7” ------------------------------- “Image7”“CUSTOM8” ------------------------------- “Image8”“CUSTOM9” ------------------------------- “Image9”“CUSTOM10” ----------------------------- “Image10”ResponseUnacceptable“Error Code” [CR] ------------------------ When the command isinvalid due to condition such as Input source.“?” [CR] --------------------------- When unknown command isreceived9.4.17 CR_IMGGMD CommandCommand “CR_IMGGMD” [CR]Details Get setting status of Standard/Real/Cinema in Image GammaAcceptable “000_%1” [CR]%1“DYN” -------------------------------- Dynamic“STD” -------------------------------- Standard“REL” -------------------------------- Real“NTR” -------------------------------- Natural“CNM” ------------------------------- CinemaResponseUnacceptable “Error Code” [CR]