Item SpecificationProtectionFunctionsMomentary Power LossRide-Thru Immediately stop after 15 ms or longer power loss <6> .Continuous operation during power loss than 2 s (standard) <7>Heatsink Overheat Protection ThermistorBraking Resistor OverheatProtection Overheat input signal for braking resistor (Optional ERF-type, 3% ED)Stall Prevention Stall Prevention is available during acceleration, deceleration, and during run.Ground Protection Electronic circuit protection <8>DC Bus Charge LED Remains lit until DC bus voltage falls below 50 VEnvironmentArea of Use IndoorsAmbient Temperature -10 to +40 °C (IP20/NEMA Type 1 enclosure), -10 to +50 °C (IP00/Open Type enclosure)Humidity 95 RH% or less (no condensation)Storage Temperature -20 to +60 °C (short-term temperature during transportation)Altitude Up to 1000 meters without derating, up to 3000 m with output current and voltage derating.Vibration/Shock10 to 20 Hz: 9.8 m/s2 <9>20 to 55 Hz: 5.9 m/s2 (2A0004 to 2A0211, 4A0002 to 4A0165, and 5A0003 to 5A0099)2.0 m/s2 (2A0250 to 2A0415, 4A0208 to 4A1200, and 5A0125 to 5A0242)Safety Standard UL 508C (Power Conversion), UL/cUL listed, CSA 22.2 No. 14-05 (Industrial Control Equipment),CE marked, RoHS compliant, EN 61800-5-1 (LVD), EN 61800-3 (EMC), IEC60529Protection Design IP00/Open Type enclosure, IP20/NEMA Type 1 enclosure <10><1> The accuracy of these values depends on motor characteristics, ambient conditions, and drive settings. Specifications may vary with different motorsand with changing motor temperature. Contact Yaskawa for consultation.<2> Disable Stall Prevention during deceleration (L3-04 = 0) when using a regenerative converter, a regenerative unit, a braking resistor or the BrakingResistor Unit. The default setting for the Stall Prevention function will interfere with the braking resistor.<3> Instantaneous average deceleration torque refers to the torque required to decelerate the motor (uncoupled from the load) from the rated motor speeddown to zero in the shortest time.<4> Actual specifications may vary depending on motor characteristics.<5> Overload protection may be triggered when operating with 150% of the rated output current if the output frequency is less than 6 Hz.<6> May be shorter due to load conditions and motor speed.<7> A separate Momentary Power Loss Ride-Thru Unit is required for models 2A0004 to 2A0056 and 4A0002 to 4A0031 if the application needs tocontinue running for up to 2 seconds during a momentary power loss.<8> Ground protection cannot be provided when the impedance of the ground fault path is too low, or when the drive is powered up while a groundfault is present at the output.<9> Models 4A0930 and 4A1200 are rated at 5.9 m/s2.<10> Removing the top protective cover or bottom conduit bracket from an IP20/NEMA Type 1 enclosure drive voids NEMA Type 1 protection whilemaintaining IP20 conformity. This is applicable to models 2A0004 to 2A0211, 4A0002 to 4A0165, and 5A0003 to 5A0242.A.2 Drive Specifications180 YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide