u E2: Motor 1 ParametersNo.(Addr.Hex) Name Description Values PageE2-01(30E) Motor Rated CurrentSets the motor nameplate full load current in amps. Automatically set duringAuto-Tuning. Default: <1>Min.: 10% of driverated currentMax.: 200% ofdrive rated current<2>106E2-02(30F) Motor Rated SlipSets the motor rated slip. Automatically set during Auto-Tuning. Default: <1>Min.: 0.00 HzMax.: 20.00 Hz–E2-03(310) Motor No-Load CurrentSets the no-load current for the motor. Automatically set during Auto-Tuning. Default: <1>Min.: 0 AMax.: E2-01 <2>–E2-04(311) Number of Motor Poles Sets the number of motor poles. Automatically set during Auto-Tuning. Default: 4Min.: 2Max.: 48 –E2-05(312) Motor Line-to-LineResistanceSets the phase-to-phase motor resistance. Automatically set duringAuto-Tuning. Default: <1>Min.: 0.000 ΩMax.: 65.000 Ω–E2-06(313) Motor Leakage InductanceSets the voltage drop due to motor leakage inductance as a percentage of motorrated voltage. Automatically set during Auto-Tuning. Default: <1>Min.: 0.0%Max.: 40.0%–E2-10(317) Motor Iron Loss for TorqueCompensationSets the motor iron loss. Default: <1>Min.: 0 WMax.: 65535 W–E2-11(318) Motor Rated PowerSets the motor rated power in kilowatts (1 HP = 0.746 kW). Automatically setduring Auto-Tuning. Default: <1>Min.: 0.00 kWMax.: 650.00 kW–<1> Default setting is dependent on parameter o2-04, Drive Model Selection.<2> The number of decimal places in the parameter value depends on the drive model 1. This value has two decimal places (0.01 A) if the drive is setfor a maximum applicable motor capacity up to and including 11 kW, and one decimal place (0.1 A) if the maximum applicable motor capacity ishigher than 11 kW.u F4: Analog Monitor Card (AO-A3)No.(Addr.Hex) Name Description Values PageF4-01(391) Terminal V1 MonitorSelectionSets the monitor signal for output from terminal V1. Set this parameter to thelast three digits of the desired Uo-oo monitor. Some U parameters areavailable only in certain control modes.Default: 102Range: 000 to 999 –F4-02(392) Terminal V1 Monitor GainSets the gain for voltage output via terminal V1. Default: 100.0%Min.: -999.9Max.: 999.9 –F4-03(393) Terminal V2 MonitorSelectionSets the monitor signal for output from terminal V2. Set this parameter to thelast three digits of the desired Uo-oo monitor. Some U parameters areavailable only in certain control modes.Default: 103Range: 000 to 999 –F4-04(394) Terminal V2 Monitor GainSets the gain for voltage output via terminal V2. Default: 50.0%Min.: -999.9Max.: 999.9 –F4-05(395) Terminal V1 Monitor BiasSets the amount of bias added to the voltage output via terminal V1. Default: 0.0%Min.: -999.9Max.: 999.9 –F4-06(396) Terminal V2 Monitor BiasSets the amount of bias added to the voltage output via terminal V2. Default: 0.0%Min.: -999.9Max.: 999.9 –F4-07(397) Terminal V1 Signal Level 0: 0 to 10 V1: -10 to 10 V Default: 0Range: 0, 1 –B.5 E: Motor ParametersYASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide 197B Parameter List