Min outputfrequency100%(Max outputfrequency)Output frequencywhen Stop commandwas enteredRun wait time tActive deceleration timeMin Baseblock Time (L2-03)Figure 4.12 Run Wait Time Depending on Output Frequencyn b2-01: DC Injection Braking Start FrequencyActive when “Ramp to Stop” is selected as the stopping method (b1-03 = 0).No. Name Setting Range Defaultb2-01 DC Injection Braking Start Frequency 0.0 to 10.0 Hz 0.5 HzV/f ControlSets the starting frequency for DC Injection Braking at Stop. When the output frequency falls below the setting of b2-01, DCInjection Braking is enabled for the time set in parameter b2-04.OutputFrequency Timeb2-04DC InjectionBrakingE1-09 Min. Frequencyb2-01 Zero Speed LevelFigure 4.13 DC Injection Braking at Stop for V/fNote: If b2-01 is set to a smaller value than E1-09 (Minimum Frequency), then DC Injection Braking will begin when the frequency falls to theE1-09 value.n b3-01: Speed Search Selection at StartDetermines if Speed Search is automatically performed when a Run command is issued.No. Parameter Name Setting Range Defaultb3-01 Speed Search Selection at Start 0, 1 0Setting 0: DisabledThis setting starts operating the drive at the minimum output frequency when the Run command is entered. If external SpeedSearch 1 or 2 is already enabled by a digital input, the drive will start operating with Speed Search.Setting 1: EnabledThis setting performs Speed Search when the Run command is entered. The drive begins running the motor after Speed Searchis complete.u EZ Sleep/Wake-up FunctionTo enable EZ Sleep/Wake-up functionality on the drive, first set parameter b5-89 to 1. The default setting for b5-89 is 0, whichdisables the EZ Sleep functionality and related parameters, except for parameter b5-91, EZ Sleep Minimum Speed.Setting b5-89 to 1 disables the existing PID Sleep function (b5-15) and enables the EZ Sleep/Wake-up functionality.EZ Sleep and Minimum Speed UnitsParameter b5-90, EZ Sleep Unit, determines the unit, range, and resolution of parameters b5-92 and b5-93. When set to Hz,the range is 0.1 to 400.0 Hz. When set to RPM, the range is 0 to 24000 RPM. Changing b5-90 will NOT automatically re-scale the values of b5-92 and b5-93.Minimum Speed4.6 Basic Drive Setup Adjustments96 YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide