4 Trial Operation4.6.3 Limitations4-144.6.3 LimitationsThe following functions cannot be used during the test without a motor.• Regeneration and dynamic brake operation• Brake output signal (The brake output signal can be checked with the I/O signal monitor function of the Sig-maWin+.)• Items marked with "×" in the following utility function table.Note: {: Can be used× : Cannot be usedFn No. ContentsCan beused or notMotor notconnectedMotor con-nectedFn000 Alarm history display { {Fn002 JOG operation { {Fn003 Origin search { {Fn004 Program JOG operation { {Fn005 Initializing parameter settings { {Fn006 Clearing alarm history { {Fn008 Absolute encoder multiturn reset and encoder alarm reset × {Fn009 Automatic tuning of analog (speed, torque) reference offset { {Fn00A Manual servo tuning of speed reference offset { {Fn00B Manual servo tuning of torque reference offset { {Fn00C Offset adjustment of analog monitor output { {Fn00D Gain adjustment of analog monitor output { {Fn00E Automatic offset-signal adjustment of the motor current detection signal × {Fn00F Manual offset-signal adjustment of the motor current detection signal × {Fn010 Write prohibited setting { {Fn011 Servomotor model display { {Fn012 Software version display { {Fn013 Multiturn limit value setting change when a multiturn limit disagreement alarmoccurs × {Fn014 Resetting configuration error in option modules { {Fn01B Vibration detection level initialization × ×Fn01E Display of SERVOPACK and servomotor ID { {Fn01F Display of servomotor ID in feedback option module { {Fn020 Origin setting × {Fn030 Software reset { {Fn200 Tuning-less levels setting × ×Fn201 Advanced autotuning × ×Fn202 Advanced autotuning by reference × ×Fn203 One-parameter tuning × ×Fn204 Anti-resonance control adjustment function × ×Fn205 Vibration suppression function × ×Fn206 EasyFFT × ×Fn207 Online vibration monitor × ×