4.6 Test Without Motor Function4-154 Trial Operation4.6.4 Operator Displays during Testing without MotorThe status display changes as shown below to show that the test without a motor is being executed.(1) Display on Panel Operator∗ The test without a motor operation in progress is indicated with tSt.Note: The test without a motor status is not displayed during alarm occurs (A.).(2) Display on Digital OperatorAn asterisk (∗) is displayed before status display to indicate the test without a motor operation is in progress.(Example: Status of power to the servomotor is OFF)Note: The test without a motor status is not displayed during alarm occurs (A.).Display Statusrun ⇔ tSt Power is supplied to the servomotor.bb ⇔ tSt Power to the servomotor is OFF.Pot ⇒ not ⇒ tSt Forward or reverse run is prohibited.Pot ⇔ tSt Forward run is prohibited.not ⇔ tSt Reverse run is prohibited.Hbb ⇔ tSt In hard-wire base block (safety) state.Displayed alternatelyAnalogDisplay Status*RUN Power is supplied to the servomotor.*BB Power to the servomotor is OFF.*PT NT Forward or reverse run is prohibited.*P-OT Forward run is prohibited.*N-OT Reverse run is prohibited.*HBB In hard-wire base block (safety) state.∗ B B − P R M / M O N −U n 0 0 0 = 0 0 0 0 0 0U n 0 0 2 = 0 0 0 0 0 0U n 0 0 8 = 0 0 0 0 0 0 0 0 0 0 0U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0