2 Panel Operator2.1.1 Names and Functions2-22.1 Overview2.1.1 Names and FunctionsPanel operator consists of display part and keys.Setting parameters, displaying status, executing utility functions, and monitoring SERVOPACK or converteroperation are possible with the panel operator.The names and functions of the keys on the panel operator are as follows.2.1.2 Display SelectionPress the MODE/SET Key to make a selection in the following order.Ԙ ԙ Ԛ ԛSERVOPACKDisplay partKeysNote: To reset the servo alarm, press the UP Key and the DOWN Key simultaneously. Be sure to remove the causeand then reset the alarm.Key No. Key Name Functionc MODE/SET Key • To select a display.• To set the set value.d UP Key To increase the set value.e DOWN Key To decrease the set value.f DATA/SHIFT Key • To display the set value by pressing this key for one second.• To move to the next digit on the left when flashing.Status Display (Refer to 2.3)Fn: Utility Function(Refer to 2.4)Pn: Parameter Setting(Refer to 2.6)Un: Monitor Display(Refer to 2.7)Power ONPressPress for one second.Press for one second.Press for one second.PressPressPressReturn toMODE/SETDATA/DATA/SHIFTMODE/SETMODE/SETMODE/SETDATA/DATA/SHIFTDATA/DATA/SHIFT(Refer to 2.2.)(Refer to 2.3.)(Refer to 2.4.)(Refer to 2.1.3.)Analog