Measuring range(funct. no.)Measuring value Signal range Range(D2h) 0 ... 3000W 0 ... 27648 nominal range--- --- underrange3 wire: 0 ... 60W(D8h)70.55W 32511 overrange0 ... 60W 0 ... 27648 nominal range--- --- underrange3 wire: 0 ... 600W(D9h)705.5W 32511 overrange0 ... 600W 0 ... 27648 nominal range--- --- underrange3 wire: 0 ... 3000W(DAh)3528W 32511 overrange0 ... 3000W 0 ... 27648 nominal range--- --- underrange4 wire: 0 ... 60W(E0h)70.55W 32511 overrange0 ... 60W 0 ... 27648 nominal range--- --- underrange4 wire: 0 ... 600W(E1h)705.5W 32511 overrange0 ... 600W 0 ... 27648 nominal range--- --- underrange4 wire: 0 ... 3000W(E2h)3528W 32511 overrange0 ... 3000W 0 ... 27648 nominal range--- --- underrange3.26.3 Diagnostic dataSo this module does not support diagnostic interrupt functions, the diagnostics data servefor information about this module. On error the corresponding channel LED of the moduleis activated and the error is registered in the diagnostics data.The following errors are listed in the diagnostics data:n Error in project engineering / parameterizationn Measuring range overflown Measuring range underflowDS - Record set for access via CPU, PROFIBUS and PROFINET. The access happensby DS 01h. Additionally the first 4 bytes may be accessed by DS 00h.IX - Index for access via CANopen. The access happens by IX 2F01h. Additionally thefirst 4 bytes may be accessed by IX 2F00h.SX - Subindex for access via EtherCAT with Index 5005h.More can be found in the according manual of your bus coupler.VIPA System SLIO Analog Input031-1LD80 - AI 4x16Bit R/RTD > Diagnostic dataHB300 | SM-AIO | | en | 17-05 299