No byte of the output area is used by the module.3.6.1 Technical dataOrder no. 031-1BB40Type SM 031Module ID 0402 15C3Current consumption/power lossCurrent consumption from backplane bus 80 mAPower loss 0.7 WTechnical data analog inputsNumber of inputs 2Cable length, shielded 200 mRated load voltage DC 24 VCurrent consumption from load voltage L+ (without load) 15 mAVoltage inputs -Min. input resistance (voltage range) -Input voltage ranges -Operational limit of voltage ranges -Operational limit of voltage ranges with SFU -Basic error limit voltage ranges -Basic error limit voltage ranges with SFU -Destruction limit voltage -Current inputs üMax. input resistance (current range) 110 ΩInput current ranges 0 mA ... +20 mA+4 mA ... +20 mAOperational limit of current ranges +/-0.3% ... +/-0.5%Operational limit of current ranges with SFU -Basic error limit current ranges +/-0.2% ... +/-0.3%Radical error limit current ranges with SFU -Destruction limit current inputs (voltage) max. 24VDestruction limit current inputs (electrical current) max. 40mAResistance inputs -Resistance ranges -Operational limit of resistor ranges -Operational limit of resistor ranges with SFU -Basic error limit -Output areaVIPA System SLIO Analog Input031-1BB40 - AI 2x12Bit 0(4)...20mA > Technical dataHB300 | SM-AIO | | en | 17-05 69