A.16 Control Mode Dependent Parameter Default ValuesThe tables below list parameters that depend on the control mode selection. Changing the control mode initializes theseparameters to the values shown here.u A1-02 (Control Mode) Dependent ParametersTable A.3 A1-02 (Control Mode) Dependent Parameters and Default ValuesNo. Name Setting Range Resolution Control Modes (A1-02)V/f (0) OLV/PM (5)b1-24 Commercial Power Switching Selection 0, 1 – 0 0b2-01 DC Injection Braking Start Frequency 0.0 to 10.0 0.1 Hz 0.5 Hz 0.5 Hzb2-04 DC Injection Braking Time at Stop 0.00 to 10.00 0.01 s 0.50 s 0.00 sb3-08 Current Control Gain during Speed Search(Speed Estimation Type) 0.00 to 6.00 – <1> 0.3b3-09 Current Control Integral Time during Speed Search(Speed Estimation Type) 0.0 to 1000.0 0.0 ms 2.00 ms 4.00 msb3-24 Speed Search Method Selection 1, 2 – 2 2b8-01 Energy Saving Control Selection 0, 1 – 0 –C2-01 S-Curve Time at Acceleration Start 0.00 to 10.00 0.01 s 0.20 s 1.00 sC4-01 Torque Compensation Gain 0.00 to 2.50 0.01 1.00 0.00C4-02 Torque Compensation Primary Delay Time 0 to 10000 1 ms 200 ms 100 msC6-02 Carrier Frequency Selection 1 to 4, F – <1> <1>E1-04 Maximum Output Frequency 40.0 to 400.0 0.1 Hz 60.0 <2>E1-05 Maximum Voltage 0.0 to 255.0 <3> 0.1 V 575 <4> <2>E1-06 Base Frequency 0.0 to 400.0 0.1 Hz 60.0 <2>E1-07 Middle Output Frequency 0.0 to 400.0 0.1 Hz 3.0 –E1-08 Middle Output Frequency Voltage 0.0 to 255.0 <3> 0.1 V 15.0 <4> –E1-09 Minimum Output Frequency 0.0 to 400.0 0.1 Hz 1.5 <2>E1-10 Minimum Output Frequency Voltage 0.0 to 255.0 <3> 0.1 V 9.0 –L1-01 Motor Overload Protection Selection 0 to 4 – 1 4L8-18 Software Current Limit Selection 0 to 1 – <5> 0L8-38 Carrier Frequency Reduction Selection 0 to 2 – <1> 0L8-40 Carrier Frequency Reduction Off Delay Time 0.00 to 2.00 0.01 s 0.50 s 0.00 s<1> Default setting value is determined by parameter o2-04, Drive Model Selection.<2> Default setting is dependent on parameter E5-01, Motor Code Selection.<3> Values shown are specific to 200 V class drives. Double the values for 400 V class drives.<4> This setting value depends on rated output current and V/f pattern selection in parameter E1-03.<5> Default setting value is determined by the drive software version.PRG: 6113 and earlier: 0PRG: 6114 and later: Default setting is dependent on parameter A1-02, Control Method SelectionA.16 Control Mode Dependent Parameter Default ValuesYASKAWA ELECTRIC SIEP C710636 10C Z1000U HVAC MATRIX Drive Programming Manual 257A Parameter List