140 APPENDIX A: S AFETY I NFORMATIONImportant SafetyInformation Installation and removal of the unit must be carried out by qualifiedpersonnel only. The unit must be earthed (grounded). The unit must be connected to an earthed (grounded) outlet to complywith European safety standards and EMC standards. Power Cord SetThis must be approved for the country where it is used: This unit operates under SELV (Safety Extra Low Voltage) conditionsaccording to IEC 950. The conditions are only maintained if theequipment to which it is connected also operates under SELV conditions. The appliance coupler (the connector to the unit and not the wall plug)must have a configuration for mating with an EN60320/IEC320 applianceinlet. The socket outlet must be near to the unit and easily accessible. You canonly remove power from the unit by disconnecting the power cord fromthe outlet.UK The supply plug must comply with BS1363 (3-pin 13amp) and be fitted with a 5A fuse which complies withBS1362. The mains cord must be or markedand be of type HO3VVF3gO.75 (minimum).Europe The supply plug must comply with CEE 7/7(“SCHUKO”). The supply plug must comply with CE123-16/VII.USA andCanada The cord set must be UL-approved and CSA certified. The minimum specification for the flexible cord is:No. 18 AWGType SV or SJ3-conductor The cord set must have a rated current capacity of atleast 10A. The attachment plug must be an earth-grounding typewith a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A,250V) configuration.Denmark The supply plug must comply with section 107-2-D1,standard DK2-1a or DK2-5a.Switzerland The supply plug must comply with SEV/ASE 1011.