18-1S E C T I O N 1 8ID Codes• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •In This Section© About the ID Codes© Service Code© Fire Marshall Code© Duress Signal© ID Code Programming© Summary of ID Code Capabilities and Privileges• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •About the ID CodesThe FOCUS 200 PLUS System supports up to 99 separate 6-digit ID codes, including service codes.Each ID code is limited to the BA group(s) it is assigned, and is capable of:• Turning the protection on.• Turning the protection off.• Performing tests of the BA sensors.• Performing the operating panel tests.• Performing the local bell tests.Code MakeupID codes are made up of six digits. All six digits of an ID code are needed to access the system. The firsttwo digits of the ID code:• Serve as the user number, and are numbered 01, 02, 03, etc., up to 99.• Are used as passcodes by the CCC when identifying the person performing a function.The last four digits of the ID code:• Serve as a PIN (Person Identification Number).• Uniquely identify the user and his assigned privileges to the system.• Serve to identify the level of access.Programmable ID Code PrivilegesThe following privileges are optional for each ID code. They are assigned to the ID code when it isentered into the system, but may be changed at any time by a user with the appropriate privilege.Privileges are limited to the BA group(s) to which the ID code is assigned.Each ID code may be assigned the ability to:• Assign ID code privileges.• Open one or more BA groups outside of the scheduled opening time without initiating an irregularopening.• Bypass and unbypass any points in the BA group(s).• Bypass VVS sensors.