Chapter 5: Local Management5-682E43-51/2E43-51R User’s GuideINTERFACE # (Selectable)This command field selects the front panel interface connector(ENET 1 to ENET 4) to which the port security settings will be applied.5.20.1 Setting the Port Level SecurityTo set the security for each repeater port on a connector, proceed asfollows:1. Use the arrow keys to highlight the INTERFACE # field.2. Use the SPACE bar to step to the appropriate interface connectornumber (ENET 1 to ENET 4).3. Use the arrow keys to highlight the STATE field for the interfaceconnector.4. Use the SPACE bar to step to the appropriate security level (Secure orNonSecure).5. Use the arrow keys to highlight the Lock/Learn field for the interfaceconnector.6. Use the SPACE bar to step to the appropriate type of security(LockOnNext or LockedOnAddr).7. If the security level chosen causes the DisablePort and SendTrapfields to display under Action On Intruder, use the arrow keys tohighlight the DisablePort field.If the security level chosen does not cause the fields to display underAction On Intruder, proceed to step 11.8. To change the DisablePort setting to NoDisable, press the SPACEbar to toggle the setting.9. Use the arrow keys to highlight the SendTrap field.10. To change the setting to NoTrap, press the SPACE bar to toggle thesetting.11. If the security state selected is LockedOnAddr, use the arrow keys tohighlight the Secure Address field for the port. Otherwise go tostep 13.12. Enter the address to lock on.