Chapter 33-100101 Multifeeder lifter motor (M1; faulty) DC controller PCB (faulty)The upper lifter sensor (PS2) does not turn ON within 6sec after the multifeeder lifter motor (M1) has turnedON.0102The lower lifter sensor (PS3) does not turn ON within 6sec after the multifeeder lifter motor (M1) has turnedON.0103 The error detection circuit of the DC controller PCBdetects overcurrent in the multifeeder lifter drive circuit.E0410001 The deck lifter motor (M2) is faulty. The deck lifter lower linit switch (SW2) isfaulty. The DC controller PCB is faulty.When the lift action of the paper deck is not completedwithin 60 secs.E0440001 The paper width set for the cassette or themultifeeder is wrong. The slide resistor is faulty.Wrong paper width for multifeeder0002 Wrong paper width for upper cassette0003 Wrong paper width for lower cassetteE0500001 Duplex paper jogging guide motor (M23;faulty) Duplex paper jogging guide home positionsensor (PS29; faulty) DC controller PCB (faulty)The duplexing unit stacking guide home position sensor(PS29) does not turn ON within 4 sec after the duplexpaper jogging guide motor (M23) has turned ON.0002The duplex paper jogging guide home position sensor(PS29) remains ON for 1 sec or more after the duplexingunit stacking guide motor (M23) has turned ON.E061Potential Control Faulthighorder 2 digitsxx=00:common error xx=01:Y xx=02:M xx=03:C xx=04:BKxx01 Potential measurement unit (faulty) DC controller PCB (faulty) Primary/Preprimary charging assembly(faulty) Preexposure lamp (faulty)The difference between VD1 measured during the 1strotation and VD1 measured during the 2nd rotation is 30V or more.xx02The difference between VD2 measured during the 1strotation and VD2 measured during the 2nd rotation is 30V or more.xx03The difference between VL1 measured during the 1strotation and VL1 measured during the 2nd rotation is 30V or more.xx04The difference between VL2 measured during the 1strotation and VL2 measured during the 2nd rotation is 30V or more.Code Cause Description