Chapter 55-79 OPTION > DECKSwitch the airassist conditions inside the deck (i.e., temperature setting on heater, air volume setting on the fan) intoa specific mode.T-5-59"Gray area" in the above table means transfer failure that occurs when the paper inside paper deck gets hot air andbecomes dry. This symptom more often applies to largesize paper than smallsize paper, because largesize paperstays longer inside paper deck.A switching from "fullspeed" into "halfspeed" or a switching from "default" into "Prevent gray area" may preventsmooth feeding, leading to a deck feeding sensor delay jam (0106).The above sequence applies to the DCcon version 2.02 and the later.Here is the one for the DCcon version 2.01 and the earlier.SetupValueRotation Speed(Fan)TemperatureControl (Heater)for SmallsizePaperTemperatureControl (Heater)for LargesizePaper0(default)Full speed (27Vdrive) Smooth feeding Smooth feeding1 Full speed (27Vdrive) Smooth feeding Prevent gray area2 For development3 Full speed (27Vdrive) Prevent gray area Prevent gray area4 Half speed (12Vdrive) Smooth feeding Smooth feeding5 Half speed (12Vdrive) Smooth feeding Prevent gray area6 For development7 Half speed (12Vdrive) Prevent gray area Prevent gray area PreviousNext |