Chapter 33-13.1 Error Code Details3.1.1 Error Code Details 0004-9338CLC5100 / CLC4000CPU on the machine's image processor and DC controller PCB is equipped with a mechanism to check the conditionof the machine (sensors, in particular). The mechanism runs a check as necessary and indicates the presence of anerror upon detection.See the tables that follow for descriptions of codes; you may check these codes using 'JAM/ERROR' under'DISPLAY' in service mode.'0001' will be used for the detailed code column of errors without a detailed code.Reference1. If the self diagnosis mechanism has been activated, you can reset the machine by turning its power switch off andthen on. This, however, does not apply to 'E000'; if allowed with the hermistor out of order, such would heat anddamage the fixing roller.2. If 'E005' (ADD CLEANING BELT) is indicated, replace the cleaning web and execute 'E005RLS' of 'FUSER'under 'FUNC' in service mode.3. Even after clearing the E indication by turning off the power switch, a description of the last E indication may bechecked using 'JAM/ERROR' under 'DISPLAY' in service mode.᤹ Clearing E0001) Start service mode, and select 'FUSER' under 'FUNC'.2) Press 'E000RLS'.3) Turn off and then on the power switch. Clearing E0051) Start service mode, and select 'FUSER' under 'FUNC'.2) Press 'E005RLS'.3) Turn off and then on the power switch. Clearing E0751) Start service mode, and select 'FMISCp' under 'FUNC'.2) Press 'E075RLS'.3) Turn off and then on the power switch. Clearing 'E004'1) Turn off the power switch.2) Disconnect and connect the power plug from and to to the power outlet.3) Turn on the power switch.