Chapter 55-35 M/C/Y/KDMAX Density Value (reference only) If the value of C, M, Y, or KDMAX is lower than 75, a fault may be assumed in the development of the colorin question. If all values of C, M, Y, and KDMAX are lower than 75, a fault may be assumed in transfer or fixing. If the value of C, M, Y, or KDMAX is 120 or higher and copies have fogging, a fault is assumed in ATR of thecolor in question. PASCAL,DMXCTT/M/C,LUTCTY/M/C/K,POFSTY/M/C/K Point to Note when Changing the SettingsIf you have changed the setting of 'PASCAL', 'DMXCTC/M/Y', 'LUTCTC/M/Y/K', or 'POFST C/M/Y/K', be sureto execute auto gradation in user mode. ADJUST > ADJMISCT-5-23POFSTY/M/C/K Use it to set data for correction of the target value for highdensity areas in auto gradation correction mode (i.e., tocorrect variation of CCD readings).You must enter the value recorded on the service labelonce again if you have initialized the RAM on the DCcontroller PCB, since initialization returns it to thestandard value. Set to optimum value at time ofshipment.Sttings range: 20 to +20 Standard: 0+: Darker᤹ : LighterADJUST > ADJMISCSub item DescriptionVCONT Switches between auto and manual for target contrast potential (VG,VDC).Settings:0: Auto (set by auto gradation correction control)1 to 8: Manual1 to 8 used for checks; normally, set it to 0 after a check.9 to 12 not used. (for factory)ADJUST > PASCALSub item Description PreviousNext |