Chapter 5᤹5-465.3 FUNCTION Operation/Inspection Mode5.3.1 FUNCTION Table5.3.1.1 FUNCTION Table 0004-7984CLC5100 / CLC4000 FUNCTION > INSTALLT-5-30FUNCTION > INSTALLSub item DescriptionINITC/M/YUse it to read in the initial value of the toner density signal (SGNL, REF) of the specified color. The value will be indicated on screen 3/4. Record it to the service label.INIT3 Reads the initial value of the toner density signal (SGNL, REF) of three colors (C, M, Y) insequence. The value will be indicated on screen 3/4. Record it to the service label.INIT7 Reads the initial value of the toner density signal (SGNL, REF) of the ATR and SALT sensorsin sequence. The value will be indicated on screens 3/4 and 4/4. Record it to the service label.SINITC/M/Y/KReads the initial value of the SALT signal (SGNL, REF) of the specified color. The value will be indicated on screen 4/4. Record it to the service label.SINIT4 Reads the initial value of the SALT signal (SGNL, REF) of four colors (C, M, Y, K) in sequence. The value will be indicated on screen 4/4. Record it to the service label.STIRC/M/Y/KStirs the starter of the specified color.STIR4 Stirs the starters of the four colors.SPLYC/M/Y/KRotates the cylinder of the developing assembly to supply starter of the specified color.IMGREG Turns on or off the image position auto correction function.0: OFF᤹ 1: ONLSNSKIL Turns on or off the toner sensor output mode for moving up/down the hopper.0: OFF᤹ 1: ON᤹᤹ Initial: 0᤹Used only at time of installation.