Chapter 5᤹5-70MRECOVRUse it to execute recovery without moving the scanner for recoverycopying after the presence of a jam or the absence of toner/oil/paper hasbeen identified.Settings: 0 to 1᤹ Standard: 00: normal operation1: no rescanning during recovery copyingConditions: RDF not used, page separation not used, auto vertical/horizontal rotation not used, doublesided copying not used, enlargementpage separation not used, reduced image page composition not used.Record any new values on the service data sheet.OHPMODESelect the maximum density when making a copy outo a transparencies.Settings range: 0 to 2᤹ Standard: 0If the value is increased, the density becomes darker.Reference: The projector for OHP has a reflection type and translucenttype. It is preferable to lower the maximum copy density value in the caseof the translucenttype projector; therefore, change the maximum copydensity setting according to a projector at user's site.SMPNUM Use it to change the range of sampling of the data representing the colorselected on an original for color conversion.Settings: 0 to 1᤹ Standard: 00: sample selected color in area of 2x2 (standard)1: sample selected color in area of 4x4Record any new values on the service data sheet.Reference: In the case of an original composed of dots, correct coloridentification may not be identified; if such is the case, set it to '1' toincrease the number of samplings.THINAPS Use it to enable auto paper selection for thin paper.Settings: 0 to 1᤹ Standard: 00: disable auto paper selection1: enable auto paper selectionRecord any new values on the service data sheet.Reference: Thin paper will not be selected if of the following modes isselected: sort, group, staple doublesidedOPTION > ROPTSub item Description