13-51 SL Controller EventArray [20]Option: Function:[95] RS Flipflop 1 See parameter 13-15 RS-FF OperandS and parameter 13-16 RS-FFOperand R.[96] RS Flipflop 2 See parameter 13-15 RS-FF OperandS and parameter 13-16 RS-FFOperand R.[97] RS Flipflop 3 See parameter 13-15 RS-FF OperandS and parameter 13-16 RS-FFOperand R.[98] RS Flipflop 4 See parameter 13-15 RS-FF OperandS and parameter 13-16 RS-FFOperand R.[99] RS Flipflop 5 See parameter 13-15 RS-FF OperandS and parameter 13-16 RS-FFOperand R.[100] Fire Mode See parameter 13-15 RS-FF OperandS and parameter 13-16 RS-FFOperand R.[101] RS Flipflop 7 See parameter 13-15 RS-FF OperandS and parameter 13-16 RS-FFOperand R.[103] Relay 1[104] Relay 2[109] Relay 7[110] Relay 8[111] Relay 9[140] ATEX ETR cur.warning[141] ATEX ETR cur.alarm[142] ATEX ETR freq.warning[143] ATEX ETR freq.alarm[144] Pressure 1Low[145] Pressure 2Low[146] Pressure 3Low[147] Pressure 4Low[148] Pressure 1High[149] Pressure 2High[150] Pressure 3High[151] Pressure 4High13-52 SL Controller ActionArray [20]Option: Function:Select the action corresponding tothe SLC event. Actions are executedwhen the corresponding event(defined in parameter 13-51 SLController Event) is evaluated astrue. The following actions areavailable for selection:[0] Disabled[1] No action[2] Select set-up 1 Changes the active set-up(parameter 0-10 Active Set-up) to 1.[3] Select set-up 2 Changes the active set-up(parameter 0-10 Active Set-up) to 2.[4] Select set-up 3 Changes the active set-up(parameter 0-10 Active Set-up) to 3.[5] Select set-up 4 Changes the active set-up(parameter 0-10 Active Set-up) to 4.If the set-up is changed, it mergeswith other set-up commandscoming from either the digitalinputs or via a fieldbus.[10] Select presetref 0Selects preset reference 0.[11] Select presetref 1Selects preset reference 1.[12] Select presetref 2Selects preset reference 2.[13] Select presetref 3Selects preset reference 3.[14] Select presetref 4Selects preset reference 4.[15] Select presetref 5Selects preset reference 5.[16] Select presetref 6Selects preset reference 6.[17] Select presetref 7Selects preset reference 7. If theactive preset reference is changed,it merges with other presetreference commands coming fromeither the digital inputs or via afieldbus.[18] Select ramp 1 Selects ramp 1.[19] Select ramp 2 Selects ramp 2.[22] Run Issues a start command to thefrequency converter.[23] Run reverse Issues a start reverse command tothe frequency converter.[24] Stop Issues a stop command to thefrequency converter.Parameter Descriptions Programming GuideM0010001 Danfoss A/S © 10/2019 All rights reserved. 1433 3