Function Set-ups parametersThe Function Set-ups parameters are grouped in the following way:Q3-10 Adv. motor settings Q3-11 Analog output Q3-12 Clock settings Q3-13 Display settingsParameter 1-90 Motor ThermalProtectionParameter 6-50 Terminal 42OutputParameter 0-70 Date and Time Parameter 0-20 Display Line 1.1SmallParameter 1-93 Thermistor Source Parameter 6-51 Terminal 42Output Min ScaleParameter 0-71 Date Format Parameter 0-21 Display Line 1.2SmallParameter 1-29 Automatic MotorAdaptation (AMA)Parameter 6-52 Terminal 42Output Max ScaleParameter 0-72 Time Format Parameter 0-22 Display Line 1.3SmallParameter 14-01 SwitchingFrequency– Parameter 0-74 DST/Summertime Parameter 0-23 Display Line 2 LargeParameter 4-53 Warning SpeedHigh– Parameter 0-76 DST/SummertimeStartParameter 0-24 Display Line 3 Large– – Parameter 0-77 DST/SummertimeEndParameter 0-37 Display Text 1– – – Parameter 0-38 Display Text 2– – – Parameter 0-39 Display Text 3Table 2.2 Q3-1 General SettingsQ3-20 Digital reference Q3-21 Analog referenceParameter 3-02 Minimum Reference Parameter 3-02 Minimum ReferenceParameter 3-03 Maximum Reference Parameter 3-03 Maximum ReferenceParameter 3-10 Preset Reference Parameter 6-10 Terminal 53 Low VoltageParameter 5-13 Terminal 29 Digital Input Parameter 6-11 Terminal 53 High VoltageParameter 5-14 Terminal 32 Digital InputParameter 5-14 Terminal 32Digital InputParameter 6-12 Terminal 53 Low CurrentParameter 5-15 Terminal 33 Digital Input Parameter 6-13 Terminal 53 High Current– Parameter 6-14 Terminal 53 Low Ref./Feedb. Value– Parameter 6-15 Terminal 53 High Ref./Feedb. ValueTable 2.3 Q3-2 Open-loop SettingsQ3-30 Single zone int. setpoint Q3-31 Single zone ext. setpoint Q3-32 Multi zone/advParameter 1-00 Configuration Mode Parameter 1-00 Configuration Mode Parameter 1-00 Configuration ModeParameter 20-12 Reference/Feedback Unit Parameter 20-12 Reference/Feedback Unit Parameter 3-15 Reference 1 SourceParameter 20-13 Minimum Reference/Feedb. Parameter 20-13 Minimum Reference/Feedb. Parameter 3-16 Reference 2 SourceParameter 20-14 Maximum Reference/Feedb. Parameter 20-14 Maximum Reference/Feedb. Parameter 20-00 Feedback 1 SourceParameter 6-22 Terminal 54 Low Current Parameter 6-10 Terminal 53 Low Voltage Parameter 20-01 Feedback 1 ConversionParameter 6-24 Terminal 54 Low Ref./Feedb.ValueParameter 6-11 Terminal 53 High Voltage Parameter 20-02 Feedback 1 Source UnitParameter 6-25 Terminal 54 High Ref./Feedb.ValueParameter 6-12 Terminal 53 Low Current Parameter 20-03 Feedback 2 SourceParameter 6-26 Terminal 54 Filter TimeConstantParameter 6-13 Terminal 53 High Current Parameter 20-04 Feedback 2 ConversionParameter 6-27 Terminal 54 Live Zero Parameter 6-14 Terminal 53 Low Ref./Feedb.ValueParameter 20-05 Feedback 2 Source UnitParameter 6-00 Live Zero Timeout Time Parameter 6-15 Terminal 53 High Ref./Feedb.ValueParameter 20-06 Feedback 3 SourceParameter 6-01 Live Zero Timeout Function Parameter 6-22 Terminal 54 Low Current Parameter 20-07 Feedback 3 ConversionParameter 20-21 Setpoint 1 Parameter 6-24 Terminal 54 Low Ref./Feedb.ValueParameter 20-08 Feedback 3 Source UnitParameter 20-81 PID Normal/ Inverse Control Parameter 6-25 Terminal 54 High Ref./Feedb.ValueParameter 20-12 Reference/Feedback UnitHow to Programme VLT® HVAC Drive FC 10220 Danfoss A/S © 10/2019 All rights reserved. M001000122