Beginning Metric Style Final Metric Style Resulting IS-IS Metric Valuewide transition narrow transition default value (10) if the originalvalue is greater than 63. Amessage is sent to the console.wide transition transition truncated value (the truncatedvalue appears in the LSP only).The original isis metric valueis displayed in the show configand show running-configcommands and is used if youchange back to transition metricstyle.Moving to transition and then to another metric style produces different results.Table 46. Metric Value when the Metric Style Changes Multiple TimesBeginning MetricStyle Next Metric Style Resulting MetricValue Next Metric Style Final Metric Valuewide transition truncated value wide original value isrecoveredwide transition transition truncated value wide transition original value isrecoveredwide transition truncated value narrow default value (10). Amessage is sent tothe logging bufferwide transition transition truncated value narrow transition default value (10). Amessage is sent tothe logging bufferLeaks from One Level to AnotherIn the following scenarios, each IS-IS level is configured with a different metric style.Table 47. Metric Value with Different Levels Configured with Different Metric StylesLevel-1 Metric Style Level-2 Metric Style Resulting Metric Valuenarrow wide original valuenarrow wide transition original valuenarrow narrow transition original valuenarrow transition original valuewide narrow truncated valuewide narrow transition truncated valuewide wide transition original valuewide transition truncated value492 Intermediate System to Intermediate System