2-12 F60 Feeder Protection System GE Multilin2.2 ORDER CODES 2 PRODUCT DESCRIPTION2The order codes for the reduced size vertical mount units with the process bus module are shown below.E3 | | | | | | | | | IEEE 1588, PRP, and IEC 61850E4 | | | | | | | | | IEEE 1588, PRP, Ethernet Global Data, and IEC 61850E6 | | | | | | | | | IEEE 1588, PRP, and PMUE7 | | | | | | | | | IEEE 1588, PRP, IEC 61850, and PMUF0 | | | | | | | | | PRP and CyberSentry Lvl1F1 | | | | | | | | | PRP, CyberSentry Lvl1, and Ethernet Global DataF3 | | | | | | | | | PRP, CyberSentry Lvl 1, and IEC 61850F4 | | | | | | | | | PRP, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850F6 | | | | | | | | | PRP, CyberSentry Lvl 1, and PMUF7 | | | | | | | | | PRP, CyberSentry Lvl 1, IEC 61850, and PMUG0 | | | | | | | | | IEEE 1588, PRP, and CyberSentry Lvl 1G1 | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, Ethernet Global DataG3 | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850G4 | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850G6 | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, and PMUG7 | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and PMUJ0 | | | | | | | | | IEC 60870-5-103J1 | | | | | | | | | IEC 60870-5-103 + EGDJ3 | | | | | | | | | IEC 60870-5-103 + IEC 61850J4 | | | | | | | | | IEC 60870-5-103 + EGD + IEC 61850J6 | | | | | | | | | IEC 60870-5-103 + PMUJ7 | | | | | | | | | IEC 60870-5-103 + IEC 61850 + PMUK0 | | | | | | | | | IEEE1588 + PRP + IEC 60870-5-103K1 | | | | | | | | | IEEE1588 + PRP + IEC 60870-5-103 + EGDK3 | | | | | | | | | IEEE1588 + PRP + IEC 60870-5-103 + IEC 61850K4 | | | | | | | | | IEEE1588 + PRP + IEC 60870-5-103 + EGD + IEC 61850K6 | | | | | | | | | IEEE1588 + PRP + IEC 60870-5-103 + PMUK7 | | | | | | | | | IEEE1588 + PRP + IEC 60870-5-103 + IEC 61850 + PMUL0 | | | | | | | | | IEC 60870-5-103 + IEEE1588 + PRP + CyberSentry Lvl 1L1 | | | | | | | | | IEC 60870-5-103 + IEEE1588 + PRP + CyberSentry Lvl 1 + EGDL3 | | | | | | | | | IEC 60870-5-103 + IEEE1588 + PRP + CyberSentry Lvl 1 + IEC 61850L4 | | | | | | | | | IEC 60870-5-103 + IEEE1588 + PRP + CyberSentry Lvl 1 + EGD + IEC 61850L6 | | | | | | | | | IEC 60870-5-103 + IEEE1588 + PRP + CyberSentry Lvl 1 + PMUL7 | | | | | | | | | IEC 60870-5-103 + IEEE1588 + PRP + CyberSentry Lvl 1 + IEC 61850 + PMUMOUNT/COATING H | | | | | | | | Horizontal (19” rack) - StandardA | | | | | | | | Horizontal (19” rack) - With harsh environmental coatingFACEPLATE/ DISPLAY C | | | | | | | English displayD | | | | | | | French displayR | | | | | | | Russian displayA | | | | | | | Chinese displayP | | | | | | | English display with 4 small and 12 large programmable pushbuttonsG | | | | | | | French display with 4 small and 12 large programmable pushbuttonsS | | | | | | | Russian display with 4 small and 12 large programmable pushbuttonsB | | | | | | | Chinese display with 4 small and 12 large programmable pushbuttonsK | | | | | | | Enhanced front panel with English displayM | | | | | | | Enhanced front panel with French displayQ | | | | | | | Enhanced front panel with Russian displayU | | | | | | | Enhanced front panel with Chinese displayL | | | | | | | Enhanced front panel with English display and user-programmable pushbuttonsN | | | | | | | Enhanced front panel with French display and user-programmable pushbuttonsT | | | | | | | Enhanced front panel with Russian display and user-programmable pushbuttonsV | | | | | | | Enhanced front panel with Chinese display and user-programmable pushbuttonsW | | | | | | | Enhanced front panel with Turkish displayY | | | | | | | Enhanced front panel with Turkish display and user-programmable pushbuttonsI | | | | | | | Enhanced front panel with German displayJ | | | | | | | Enhanced front panel with German display and user-programmable pushbuttonsPOWER SUPPLY(redundant supply mustbe same type as main supply)H | | | | | | 125 / 250 V AC/DC power supplyH | | | | | SH 125 / 250 V AC/DC with redundant 125 / 250 V AC/DC power supplyL | | | | | | 24 to 48 V (DC only) power supplyL | | | | | SL 24 to 48 V (DC only) with redundant 24 to 48 V DC power supplyPROCESS BUS MODULE | 81 | | | | Eight-port digital process bus moduleDIGITAL INPUTS/OUTPUTS XX XX XX XX XX No Module4A 4A | 4 Solid-State (no monitoring) MOSFET outputs4B 4B | 4 Solid-State (voltage with optional current) MOSFET outputs4C 4C | 4 Solid-State (current with optional voltage) MOSFET outputs4D 4D | 16 digital inputs with Auto-Burnishing (maximum of three modules within a case)4L 4L | 14 Form-A (no monitoring) Latching outputs67 67 | 8 Form-A (no monitoring) outputs6A 6A | 2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 digital inputs6B 6B | 2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 digital inputs6C 6C | 8 Form-C outputs6D 6D | 16 digital inputs6E 6E | 4 Form-C outputs, 8 digital inputs6F 6F | 8 Fast Form-C outputs6G 6G | 4 Form-A (voltage with optional current) outputs, 8 digital inputs6H 6H | 6 Form-A (voltage with optional current) outputs, 4 digital inputs6K 6K | 4 Form-C and 4 Fast Form-C outputs6L 6L | 2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 digital inputs6M 6M | 2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 digital inputs6N 6N | 4 Form-A (current with optional voltage) outputs, 8 digital inputs6P 6P | 6 Form-A (current with optional voltage) outputs, 4 digital inputs6R 6R | 2 Form-A (no monitoring) and 2 Form-C outputs, 8 digital inputs6S 6S | 2 Form-A (no monitoring) and 4 Form-C outputs, 4 digital inputs6T 6T | 4 Form-A (no monitoring) outputs, 8 digital inputs6U 6U | 6 Form-A (no monitoring) outputs, 4 digital inputs6V 6V | 2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 digital inputsINTER-RELAYCOMMUNICATIONS(select a maximum of 1 per unit)2A C37.94SM, 1300 nm single-mode, ELED, 1 channel single-mode2B C37.94SM, 1300 nm single-mode, ELED, 2 channel single-mode2E Bi-phase, single channel2F Bi-phase, dual channel2G IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel2H IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels2I Channel 1 - IEEE C37.94, MM, 64/128 kbps; Channel 2 - 1300 nm, single-mode, Laser2J Channel 1 - IEEE C37.94, MM, 64/128 kbps; Channel 2 - 1550 nm, single-mode, Laser72 1550 nm, single-mode, Laser, 1 Channel73 1550 nm, single-mode, Laser, 2 Channel74 Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, Laser75 Channel 1 - G.703; Channel 2 - 1550 nm, single-mode Laser76 IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel77 IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels7A 820 nm, multimode, LED, 1 Channel7B 1300 nm, multimode, LED, 1 Channel7C 1300 nm, single-mode, ELED, 1 Channel7D 1300 nm, single-mode, Laser, 1 Channel7E Channel 1 - G.703; Channel 2 - 820 nm, multimode7F Channel 1 - G.703; Channel 2 - 1300 nm, multimode7G Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED7H 820 nm, multimode, LED, 2 Channels7I 1300 nm, multimode, LED, 2 Channels7J 1300 nm, single-mode, ELED, 2 Channels7K 1300 nm, single-mode, Laser, 2 Channels7L Channel 1 - RS422; Channel 2 - 820 nm, multimode, LED7M Channel 1 - RS422; Channel 2 - 1300 nm, multimode, LED7N Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED7P Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, Laser7Q Channel 1 - G.703; Channel 2 - 1300 nm, single-mode Laser7R G.703, 1 Channel7S G.703, 2 Channels7T RS422, 1 Channel7W RS422, 2 ChannelsTable 2–6: F60 ORDER CODES (HORIZONTAL UNITS WITH PROCESS BUS)F60 - * ** - * * * - F ** - H ** - M ** - P ** - U ** - W/X ** Full Size Horizontal Mount