GE Multilin F60 Feeder Protection System B-67APPENDIX B B.4 MEMORY MAPPINGBC350 ...Repeated for Virtual Output 69C358 ...Repeated for Virtual Output 70C360 ...Repeated for Virtual Output 71C368 ...Repeated for Virtual Output 72C370 ...Repeated for Virtual Output 73C378 ...Repeated for Virtual Output 74C380 ...Repeated for Virtual Output 75C388 ...Repeated for Virtual Output 76C390 ...Repeated for Virtual Output 77C398 ...Repeated for Virtual Output 78C3A0 ...Repeated for Virtual Output 79C3A8 ...Repeated for Virtual Output 80C3B0 ...Repeated for Virtual Output 81C3B8 ...Repeated for Virtual Output 82C3C0 ...Repeated for Virtual Output 83C3C8 ...Repeated for Virtual Output 84C3D0 ...Repeated for Virtual Output 85C3D8 ...Repeated for Virtual Output 86C3E0 ...Repeated for Virtual Output 87C3E8 ...Repeated for Virtual Output 88C3F0 ...Repeated for Virtual Output 89C3F8 ...Repeated for Virtual Output 90C400 ...Repeated for Virtual Output 91C408 ...Repeated for Virtual Output 92C410 ...Repeated for Virtual Output 93C418 ...Repeated for Virtual Output 94C420 ...Repeated for Virtual Output 95C428 ...Repeated for Virtual Output 96Mandatory (Read/Write Setting or Command)C430 Test Mode Function 0 to 2 --- 1 F245 0 (Disabled)C431 Force VFD and LED 0 to 1 --- 1 F126 0 (No)C432 Test Mode Initiate 0 to 4294967295 --- 1 F300 1Clear Commands (Read/Write)C434 Clear All Relay Records Command 0 to 1 --- 1 F126 0 (No)Mandatory (Read Only)C435 DSP Advanced Diagnostics Active 0 to 1 -- 1 F126 0 (No)C436 Synchrophasor Feature Active 0 to 1 -- 1 F126 0 (No)Mandatory (Read/Write Command)C437 Relay Reboot Command 0 to 1 --- 1 F126 0 (No)C438 Save Volatile Data 0 to 1 --- 1 F126 0 (No)Clear Records (Read/Write Setting)C446 Clear Demand Operand 0 to 4294967295 --- 1 F300 0C450 Clear Fault Reports Operand 0 to 4294967295 --- 1 F300 0C454 Clear Event Records Operand 0 to 4294967295 --- 1 F300 0C456 Clear Oscillography Operand 0 to 4294967295 --- 1 F300 0C458 Clear Data Logger Operand 0 to 4294967295 --- 1 F300 0C45A Clear Breaker 1 Arcing Current Operand 0 to 4294967295 --- 1 F300 0C45C Clear Breaker 2 Arcing Current Operand 0 to 4294967295 --- 1 F300 0C468 Clear Energy Operand 0 to 4294967295 --- 1 F300 0C46A Clear Hi-Z Records Operand 0 to 4294967295 --- 1 F300 0C46C Clear Unauthorized Access Operand 0 to 4294967295 --- 1 F300 0C470 Clear Platform Direct Input/Output Statistics Operand 0 to 4294967295 --- 1 F300 0C472 Reserved (13 items) --- --- --- F001 0Table B–10: MODBUS MEMORY MAP (Sheet 59 of 70)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT