Part No. 34032 Genie S-80 & Genie S-85 4 - 25Service Manual - First Edition Section 4 - Scheduled Maintenance ProceduresB-26Check the Hydraulic Limit SwitchLinkage1 Remove the drive chassis steer-end cover.2 Extend and retract the axle through 2 cyclesand visually inspect the linkage for damage. Besure the valve actuator is functioning properly.3 Be sure the lock nut is properly tightened.4 Repeat procedure for the non-steer end axle.a lock nutb linkage rodc springd valve actuatore limit switch valveIf the linkage functioningincorrectly, See 15-3, How to SetUp the Hydraulic Limit SwitchLinkage.TABLE B PROCEDURESResult: The descent alarm should sound whenthe control handle is held down.6 Press down the foot switch. Move the drivecontrol handle off center, hold for a momentand then release it. Move the drive controlhandle off center in the opposite direction, holdfor a moment and then release it.Result: The travel alarm should sound whenthe drive control handle is moved off center ineither direction.B-25Perform Hydraulic Oil AnalysisSee D-1, Test or Replace the Hydraulic Oil.edcba