v Follow the suggested actions in the order in which they are listed in the Action column until the problem issolved.v See Chapter 5, “Parts listing,” on page 153 to check if a component is a consumable, structural, or FRU part.v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trainedtechnician.Symptom ActionThe server does not turn off. 1. Determine whether you are using an Advanced Configuration and PowerInterface (ACPI) or a non-ACPI operating system. If you are using a non-ACPIoperating system, complete the following steps:a. Press Ctrl+Alt+Delete.b. Turn off the server by pressing the power-control button and hold it downfor 5 seconds.c. Restart the server.d. If the server fails POST and the power-control button does not work,disconnect the ac power cord for 20 seconds; then, reconnect the ac powercord and restart the server.2. If the problem remains or if you are using an ACPI-aware operating system,suspect the system board.The server unexpectedly shutsdown, and the LEDs on theoperator information panel arenot lit.See “Solving undetermined problems” on page 148.Serial-device problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problem issolved.v See Chapter 5, “Parts listing,” on page 153 to check if a component is a consumable, structural, or FRU part.v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trainedtechnician.Symptom ActionThe number of serial ports thatare identified by the operatingsystem is less than the numberof installed serial ports.1. Make sure that:v Each port is assigned a unique address in the Setup utility and none of theserial ports is disabled.v The serial-port adapter (if one is present) is seated correctly.2. Reseat the serial port adapter.3. Replace the serial port adapter.A serial device does not work. 1. Make sure that:v The device is compatible with the server.v The serial port is enabled and is assigned a unique address.v The device is connected to the correct connector (see “Rear view” on page18).2. Reseat the following components:a. Failing serial deviceb. Serial cable3. Replace the components listed in step 2 one at a time, in the order shown,restarting the server each time.4. (Trained technician only) Replace the system board.144 System x3650 M4 BD Type 5466: Installation and Service Guide